diff --git a/README.md b/README.md index a2b6245..d91708e 100644 --- a/README.md +++ b/README.md @@ -149,7 +149,7 @@ Set the following in config.yaml under inverters section. * Level: 2 - This should be everything your inverter supports * Level: 3 - This will try every register, you will get lots of 0/65535 responses for registers not supported. -* smart_meter: True - Set to true if you have a smart reader installed, this will return power usage at the meter box, without it you can not calculate house power usage. +* smart_meter: True - (_Only needed for SG* Models_) Set to true if you have a smart meter installed, this will return power usage at the meter box, without it you can not calculate house power usage. Hybrid inverters will provide this by default (load_power_hybrid) ### Useful Registers: This is just a brief list of registers I have found useful @@ -159,19 +159,23 @@ This is just a brief list of registers I have found useful **total_running_time** - Total Hours inverter has been powered on since install **internal_temperature** - Internal temperature of the Inverter **total_active_power** - Current power being generated by the inverter in Watts -**meter_power** - Power usage at the meter box, needs a smart meter installed. +ve means consuming from the grid, -ve means exporting to the grid +**meter_power** - (_SG* Models_)Power usage at the meter box, needs a smart meter installed. +ve means consuming from the grid, -ve means exporting to the grid **load_power** - Power being consumed in total -**export_to_grid** - How much being currently exported to the grid. This is calculated from meter_power if -ve value, returned as a positive value -**import_from_grid** - How much being currently imported from grid. This is calculated from meter_power if +ve value +**load_power_hybrid** - (_SH* Models only_) Power being consumed in total +**export_to_grid** - How much being currently exported to the grid. +For SG* Models this is calculated from meter_power if -ve value, returned as a positive value. (_For Hybrid models export_power_hybrid is used_) +**import_from_grid** - How much being currently imported from grid. This is calculated from meter_power if +ve value (_for hybrid models export_power_hybrid [will be negative when importing from grid] is used) **timestamp** - Last time data was collected, based on Inverters clock by default
## Home Assistant setup -In the SunGather config.yaml you need to set the smart_meter if you have one; +In the SunGather config.yaml you need to set the smart_meter if you have one +_For Hybrid Models smart_meter doesn't need to get enabled_ ``` +# Only for SG* Models smart_meter: True ``` @@ -221,6 +225,8 @@ Solar Panels > Solar Production -> Solar Production (Sungather) ## Tested * SG7.0RT with WiNet-S Dongle * SG10RT with WiNet-S Dongle and Ethernet (Credit: @rark-ha) +* SH6.0RT with WiNet-S Dongle +* SH10RT with WiNet-S Dongle