Merge branch 'bohdan-s:main' into bohdan-s-main

This commit is contained in:
benni336
2022-03-17 01:50:17 +01:00
committed by GitHub
14 changed files with 1110 additions and 264 deletions
+118
View File
@@ -0,0 +1,118 @@
config.yaml
*.log.*
docs/
# Byte-compiled / optimized / DLL files
__pycache__/
*.py[cod]
*$py.class
# C extensions
*.so
# Distribution / packaging
.Python
build/
develop-eggs/
dist/
downloads/
eggs/
.eggs/
lib/
lib64/
parts/
sdist/
var/
wheels/
*.egg-info/
.installed.cfg
*.egg
MANIFEST
# PyInstaller
# Usually these files are written by a python script from a template
# before PyInstaller builds the exe, so as to inject date/other infos into it.
*.manifest
*.spec
# Installer logs
pip-log.txt
pip-delete-this-directory.txt
# Unit test / coverage reports
htmlcov/
.tox/
.nox/
.coverage
.coverage.*
.cache
nosetests.xml
coverage.xml
*.cover
.hypothesis/
.pytest_cache/
# Translations
*.mo
*.pot
# Django stuff:
*.log
local_settings.py
db.sqlite3
# Flask stuff:
instance/
.webassets-cache
# Scrapy stuff:
.scrapy
# Sphinx documentation
docs/_build/
# PyBuilder
target/
# Jupyter Notebook
.ipynb_checkpoints
# IPython
profile_default/
ipython_config.py
# pyenv
.python-version
# celery beat schedule file
celerybeat-schedule
# SageMath parsed files
*.sage.py
# Environments
.env
.venv
env/
venv/
ENV/
env.bak/
venv.bak/
# Spyder project settings
.spyderproject
.spyproject
# Rope project settings
.ropeproject
# mkdocs documentation
/site
# mypy
.mypy_cache/
.dmypy.json
dmypy.json
# Pyre type checker
.pyre/
+1
View File
@@ -1,4 +1,5 @@
config.yaml
*.log.*
# Byte-compiled / optimized / DLL files
__pycache__/
+5 -2
View File
@@ -5,13 +5,16 @@ RUN useradd sungather
WORKDIR /usr/src/sungather
COPY requirements.txt ./
RUN pip install --no-cache-dir --upgrade -r requirements.txt
# pycryptodomex 3.14 currently fails to compile for arm64
#RUN pip install --no-cache-dir --upgrade -r requirements.txt
RUN pip install --no-cache-dir --upgrade pycryptodomex==3.11.0 -r requirements.txt
COPY SunGather/ .
VOLUME /logs
VOLUME /config
COPY SunGather/config-example.yaml /config/config.yaml
USER sungather
CMD [ "python", "sungather.py", "-c", "/config/config.yaml" ]
CMD [ "python", "sungather.py", "-c", "/config/config.yaml", "-l", "/logs/" ]
+27 -61
View File
@@ -9,12 +9,14 @@
<br />
<div align="center">
<h2 align="center">SunGather</h3>
<h2 align="center">SunGather</h2>
<p align="center">
Collect data from Sungrow Inverters using ModbusTcpClient, <a href="https://github.com/rpvelloso/Sungrow-Modbus">SungrowModbusTcpClient</a> or <a href="https://github.com/bohdan-s/SungrowModbusWebClient">SungrowModbusWebClient</a> and export to various locations.
<br />
<br />
<a href="https://sungather.app">Website Sungather.app</a>
·
<a href="https://github.com/bohdan-s/SunGather/issues">Report Bug</a>
·
<a href="https://github.com/bohdan-s/SunGather/issues">Request Feature</a>
@@ -30,7 +32,7 @@ Access ModBus data from almost any network connected Sungow Inverter.
On first connection the tool will query your inverter, retrieve the model and return the correct registers for your device. No more searching registers or creating model files.
Register information based on official documentation: <a href="https://github.com/bohdan-s/Sungrow-Inverter/blob/main/Modbus%20Information/Communication%20Protocol%20of%20PV%20Grid-Connected%20String%20Inverters_V1.1.37_EN.pdf">Communication Protocol of PV Grid-Connected String Inverters</a> and <a hreh="https://github.com/bohdan-s/Sungrow-Inverter/blob/main/Modbus%20Information/communication-protocol-of-residential-hybrid-inverterv1.0.20-1.pdf">Communication Protocol of Residential Hybrid Inverters</a>
Register information based on official documentation: <a href="https://github.com/bohdan-s/Sungrow-Inverter/blob/main/Modbus%20Information/Communication%20Protocol%20of%20PV%20Grid-Connected%20String%20Inverters_V1.1.37_EN.pdf">Communication Protocol of PV Grid-Connected String Inverters</a> and <a href="https://github.com/bohdan-s/Sungrow-Inverter/blob/main/Modbus%20Information/communication-protocol-of-residential-hybrid-inverterv1.0.20-1.pdf">Communication Protocol of Residential Hybrid Inverters</a>
Has multiple export locations out of the box:
* Console - Log directly to screen
@@ -51,64 +53,19 @@ I have learned a lot from the following projects, THANK YOU
## Raodmap / TO DO
* Full Home Assistant integration, as HACS addon
## Updates
**0.3.2**
* Added logging to file
* Hopefully better connection recovery
* Bug fixes
**0.3.0**
**IMPORTANT: If updating from v0.1.x or v0.2.x please check config against config-example. some options for MQTT and PVOutput have changed**
* Heaps bug fixes
* Fixed PVOutput not working after midnight
* MQTT now auto-reconnects
* MQTT/PVOutput now verify values exist before trying to publish
* Rasberry Pi Docker support
* lots more...
**0.2.2**
* Minor bug fixes
* Add support for some inverter scrapes to fail
* Add support for zero_on_standby, this will 0 registers like temp that 'stick' to the last value when the inverter goes into standy. Handy if you want to graph 0 instead of the last read overnight
**0.2.1**
* Minor bug fixes
* Updated config-example.yaml to clearly explain each option and if it is required or optional
* Replace is_running with run_state, was using bool which was causing errors in MQTT, run_state uses "ON" and "OFF"
**0.2.0**
**IMPORTANT: If updating from v0.1.x please check config against config-example. some options for MQTT and PVOutput have changed**
* Re-write to Inverter scanning code, improved performance and more resilient to failures
* Re-write to PVOutput code, now uploads every 5 minutes as per API documentation, averages all data points over the 5 min window to reduce random high/low values
* Re-Write to MQTT code, now supports multiple sensor types
**0.1.3**
* Improved error recovery, e.g. Inverter powers down overnight
**0.1.2**
* Added InfluxDB export
**0.1.1**
* Added docker image
* Added simple http web server
* Improved recovery when errors (See: SungrowModbusWebClient 0.2.6)
**0.1.0**
Initial build
### Built With
* [Python3](https://www.python.org/)
### Requires
* [paho-mqtt>=1.5.1](https://pypi.org/project/paho-mqtt/)
* [pymodbus>=2.4.0](https://pypi.org/project/pymodbus/)
* [SungrowModbusTcpClient>=0.1.6](https://pypi.org/project/SungrowModbusTcpClient/)
* [SungrowModbusWebClient>=0.2.6](https://pypi.org/project/SungrowModbusWebClient/)
* [PyYAML>=6.0] (https://pypi.org/project/PyYAML/)
* [requests>=2.26.0](https://pypi.org/project/requests/)
* [influxdb-client>=1.24.0](https://pypi.org/project/influxdb-client/)
* [paho-mqtt](https://pypi.org/project/paho-mqtt/)
* [pymodbus](https://pypi.org/project/pymodbus/)
* [SungrowModbusTcpClient](https://pypi.org/project/SungrowModbusTcpClient/)
* [SungrowModbusWebClient](https://pypi.org/project/SungrowModbusWebClient/)
* [PyYAML](https://pypi.org/project/PyYAML/)
* [requests](https://pypi.org/project/requests/)
* [influxdb-client](https://pypi.org/project/influxdb-client/)
<p align="right">(<a href="#top">back to top</a>)</p>
@@ -130,13 +87,21 @@ python3 sungather.py
```
# Docker
docker run options:
-v {path to}/config.yaml:/config/config.yaml <- Set Config File Location
-v {logpath}:/logs <- Set Log folder Location if using log to file (also set log_file in config.yaml)
-e TZ=Australia/Sydney <- Set Timezone
-p 8080:8080 <- Set Web server port (only if using the webserver export)
```sh
docker pull bohdans/sungather
docker run -v {path to}/config.yaml:/config/config.yaml -e TZ=Australia/Sydney --name sungather bohdans/sungather
```
or if using the webserver export
```sh
docker run -v {path to}/config.yaml:/config/config.yaml -e TZ=Australia/Sydney -p 8080:8080 --name sungather bohdans/sungather
docker run -d --name sungather \
--restart always \
-v {path to}/config.yaml:/config/config.yaml \
-v {logpath}:/logs \
-e TZ=Australia/Sydney \
-p 8080:8080 \
bohdans/sungather
```
Note: replace Australia/Sydney with relevant timezone
<p align="right">(<a href="#top">back to top</a>)</p>
@@ -219,6 +184,8 @@ sensor.inverter_meter_power
```
The Inverter reports Power (W), but HA needs Energy (Wh).
You can use a "Riemann sum integral" (called integration) to convert it.
Put the following into your sensors.yaml
```
sensor:
@@ -283,6 +250,7 @@ docker push bohdans/sungather -a
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- LICENSE -->
## License
@@ -290,7 +258,6 @@ Distributed under the GPL3 License. See `LICENSE.txt` for more information.
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- CONTACT -->
## Contact
@@ -298,7 +265,6 @@ Project Link: [https://github.com/bohdan-s/SungrowModbusWebClient](https://githu
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- ACKNOWLEDGMENTS -->
## Acknowledgments
+4
View File
@@ -68,8 +68,12 @@ class export_mqtt(object):
return name.lower().replace(' ','_')
def publish(self, inverter):
try:
if not self.mqtt_client.is_connected():
logging.warning(f'MQTT: Server Disconnected; {self.mqtt_queue.__len__()} messages queued, will automatically attempt to reconnect')
except Exception as err:
logging.warning(f'MQTT: Server Error; Server not configured')
return False
# qos=0 is set, so no acknowledgment is sent, rending this check useless
#elif self.mqtt_queue.__len__() > 10:
# logging.warning(f'MQTT: {self.mqtt_queue.__len__()} messages queued, this may be due to a MQTT server issue')
+15 -4
View File
@@ -125,10 +125,17 @@ class export_pvoutput(object):
# Add new data to old data and increase count of data points
for parameter in self.pvoutput_parameters:
value = inverter.getRegisterValue(parameter.get('register'))
if parameter.get('multiple'):
value = value * parameter.get('multiple')
if self.collected_data.get(parameter.get('name'),False):
# If using Cumulative Energy we just need the last data point, not the average
if parameter.get('name') == 'v1' and (self.pvoutput_config['cumulative_flag'] == 1 or self.pvoutput_config['cumulative_flag'] == 2):
self.collected_data[parameter.get('name')] = value
elif parameter.get('name') == 'v3' and (self.pvoutput_config['cumulative_flag'] == 1 or self.pvoutput_config['cumulative_flag'] == 3):
self.collected_data[parameter.get('name')] = value
# Add the last data point to the previous data point if exists, otherwise set as the last data point
elif self.collected_data.get(parameter.get('name'),False):
self.collected_data[parameter.get('name')] = round(self.collected_data[parameter.get('name')] + value,3)
else:
self.collected_data[parameter.get('name')] = value
@@ -143,8 +150,7 @@ class export_pvoutput(object):
return True
def publish(self, inverter):
self.collect_data(inverter)
if self.collect_data(inverter):
# Process data points every status_interval
if((time.time() - self.last_publish) >= (self.status_interval * 60)):
any_data = False
@@ -154,7 +160,11 @@ class export_pvoutput(object):
for x in range(1, 13):
field = 'v' + str(x)
if self.collected_data.get(field):
if x == 6 or x == 7: # Round to 1 decimal place
if x == 1 and (self.pvoutput_config['cumulative_flag'] == 1 or self.pvoutput_config['cumulative_flag'] == 2):
value = int(self.collected_data[field])
elif x == 3 and (self.pvoutput_config['cumulative_flag'] == 1 or self.pvoutput_config['cumulative_flag'] == 3):
value = int(self.collected_data[field])
elif x == 6 or x == 7: # Round to 1 decimal place
value = round(self.collected_data[field] / self.collected_data['count'], 1)
else: # Getting errors when uploading decimals for power/energy so return INT
value = int((self.collected_data[field] / self.collected_data['count']))
@@ -200,6 +210,7 @@ class export_pvoutput(object):
if response.status_code != requests.codes.ok:
logging.error(f"PVOutput: Upload Failed; {str(response.status_code)} Message; {str(response.text)}")
logging.error("PVOutput: Request; " + self.url_addbatchstatus + ", " + str(self.headers) + " : " + str(payload))
else:
self.batch_data = []
self.last_publish = time.time()
+1 -1
View File
@@ -43,7 +43,7 @@ class MyServer(BaseHTTPRequestHandler):
self.send_response(200)
self.send_header("Content-type", "text/html")
self.end_headers()
self.wfile.write(bytes("<html><head><title>SunGather</title><meta http-equiv='refresh' content='15'></head>", "utf-8"))
self.wfile.write(bytes("<html><head><title>SunGather</title><meta charset='UTF-8'><meta http-equiv='refresh' content='15'></head>", "utf-8"))
self.wfile.write(bytes("<body>", "utf-8"))
self.wfile.write(bytes(export_webserver.html_body, "utf-8"))
self.wfile.write(bytes("</table>", "utf-8"))
+504 -58
View File
@@ -1,5 +1,26 @@
version: 0.2.0
registers:
- read:
- name: "protocol_number"
level: 2
address: 4950
datatype: "U32"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "protocol_version"
level: 2
address: 4952
datatype: "U32"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "arm_software_version"
level: 2
address: 4954
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "dsp_software_version"
level: 2
address: 4969
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "serial_number"
level: 3
address: 4990
@@ -174,6 +195,9 @@ registers:
value: "SG5K-D"
- response: 0x2403
value: "SG8K-D"
# RS Series
- response: 0x2606
value: "SG5.0RS"
- name: "nominal_active_power"
level: 2
address: 5001
@@ -189,7 +213,7 @@ registers:
value: "2P"
- response: 1
value: "3P4L"
- response: 1
- response: 2
value: "3PSL"
- name: "daily_power_yields"
level: 0
@@ -201,12 +225,12 @@ registers:
level: 1
address: 5004
datatype: "U32"
unit: "KWh"
unit: "kWh"
- name: "total_running_time"
level: 1
address: 5006
datatype: "U32"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
unit: "h"
- name: "internal_temperature"
level: 1
@@ -218,7 +242,7 @@ registers:
level: 1
address: 5009
datatype: "U32"
models: ["SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT", "SG33K3J", "SG36KTL-M", "SG40KTL-M", "SG50KTL", "SG50KTL-M", "SG60KTL", "SG60KTL-M", "SG60KU-M", "SG80KTL", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG33CX", "SG40CX", "SG50CX", "SG110CX", "SG250HX", "SG30CX", "SG36CX-US", "SG60CX-US", "SG250HX-US", "SG250HX-IN", "SG25CX-SA", "SG100CX", "SG75CX", "SG225HX"]
models: ["SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG33K3J","SG36KTL-M","SG40KTL-M","SG50KTL","SG50KTL-M","SG60KTL","SG60KTL-M","SG60KU-M","SG80KTL","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG100CX","SG75CX","SG225HX"]
unit: "VA"
- name: "mppt_1_voltage"
level: 2
@@ -238,14 +262,14 @@ registers:
datatype: "U16"
accuracy: 0.1
unit: "V"
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","SG50KTL-M-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","SG50KTL-M-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "mppt_2_current"
level: 2
address: 5014
datatype: "U16"
accuracy: 0.1
unit: "A"
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","SG50KTL-M-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","SG50KTL-M-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "mppt_3_voltage"
level: 2
address: 5015
@@ -263,7 +287,7 @@ registers:
- name: "total_dc_power"
level: 2
address: 5017
datatype: "S32" # Documentation says Unsigned, but seems to be returning Signed 32bit
datatype: "U32" # Documentation says Unsigned, but seems to be returning Signed 32bit
unit: "W"
- name: "phase_a_voltage"
level: 1
@@ -289,7 +313,7 @@ registers:
datatype: "S16" # Documentation says Unsigned, but seems to be returning Signed 16bit
accuracy: 0.1
unit: "A"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "phase_b_current"
level: 2
address: 5023
@@ -318,7 +342,7 @@ registers:
address: 5031
datatype: "U32"
unit: "W"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "total_reactive_power"
level: 2
address: 5033
@@ -367,53 +391,53 @@ registers:
value: "Fault"
- response: 0x2500
value: "Communication Fault"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "alarm_time_year"
level: 3
address: 5039
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "alarm_time_month"
level: 3
address: 5040
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "alarm_time_day"
level: 3
address: 5041
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "alarm_time_hour"
level: 3
address: 5042
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "alarm_time_minute"
level: 3
address: 5043
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "alarm_time_second"
level: 3
address: 5045
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "alarm_code_1" # See Appendix 3
level: 3
address: 5045
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
# - name: "Reserved"
# address: 5046 - 5048
# datatype: "U16"
# models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
# models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "nominal_reactive_power"
level: 2
address: 5049
datatype: "U16"
accuracy: 0.1
unit: "kVar"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
# - name: "Reserved"
# address: 5050 - 5070
# datatype: "U32"
@@ -422,7 +446,7 @@ registers:
address: 5071
datatype: "U16"
unit: "k-ohm"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
# - name: "Reserved"
# address: 5072
# datatype: "U16"
@@ -432,14 +456,14 @@ registers:
level: 2
address: 5077
datatype: "U32"
unit: "w"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
unit: "W"
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "reactive_power_regulation_setpoint"
level: 2
address: 5079
datatype: "S32"
unit: "Var"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "work_state_2" # See Appendix 2
level: 2
address: 5081
@@ -473,39 +497,38 @@ registers:
value: "Total Run Bit"
- response: 18
value: "Total Fault Bit"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG5K-D","SG8K-D"]
- name: "meter_power"
level: 1
address: 5083
datatype: "S32"
indicator: True
smart_meter: True
unit: "w"
unit: "W"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M"]
- name: "meter_a_phase_power"
level: 2
address: 5085
datatype: "S32"
unit: "w"
unit: "W"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M"]
- name: "meter_b_phase_power"
level: 2
address: 5087
datatype: "S32"
unit: "w"
unit: "W"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M"]
- name: "meter_c_phase_power"
level: 2
address: 5089
datatype: "S32"
unit: "w"
unit: "W"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M"]
- name: "load_power"
level: 1
address: 5091
datatype: "S32"
smart_meter: True
unit: "w"
unit: "W"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M"]
- name: "daily_export_energy"
level: 1
@@ -636,7 +659,7 @@ registers:
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "mppt_9_voltage"
level: 2
address: 5130
@@ -709,32 +732,32 @@ registers:
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG100CX","SG75CX","SG225HX","SG5K-D","SG8K-D"]
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG100CX","SG75CX","SG225HX","SG5K-D","SG8K-D"]
- name: "negative_voltage_to_the_ground"
level: 2
address: 5146
datatype: "S16"
accuracy: 0.1
unit: "V"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "bus_voltage"
level: 2
address: 5147
datatype: "U16"
accuracy: 0.1
unit: "V"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "grid_frequency"
level: 2
address: 5148
datatype: "U16"
accuracy: 0.01
unit: "Hz"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG100CX","SG75CX","SG225HX","SG5K-D","SG8K-D"]
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG100CX","SG75CX","SG225HX","SG5K-D","SG8K-D"]
# - name: "Reserved"
# address: 5149
# datatype: "U16"
# multiple: 0.01
# accuracy: 0.01
- name: "pid_work_state"
level: 2
address: 5150
@@ -746,7 +769,7 @@ registers:
value: "Anti-PID Operation"
- response: 8
value: "PID Abnormity"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG100CX","SG75CX","SG225HX"]
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG100CX","SG75CX","SG225HX"]
- name: "pid_alarm_code"
level: 2
address: 5151
@@ -758,22 +781,23 @@ registers:
value: "PID function abnormal"
- response: 434
value: "PID overvoltage/overcurrent protection"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
# - name: "Reserved"
# address: 5152
# datatype: "U16"
# Following 2 registers are not in the documentation, but other projects are using them
- name: "export_power"
level: 3
level: 2
address: 5216
datatype: "U16"
indicator: True
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
datatype: "S32"
unit: "W"
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "power_meter"
level: 3
level: 2
address: 5218
datatype: "U16"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
datatype: "S32"
unit: "W"
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
# - name: "Reserved"
# address: 5153-7012
##### Residential Hybrid Inverters only START
@@ -781,81 +805,109 @@ registers:
level: 1
address: 6100
datatype: "U16"
unit: "W"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "daily_pv_energy_yields"
level: 1
address: 6196
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "monthly_pv_energy_yields"
level: 2
address: 6227
datatype: "U16"
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "yearly_pv_energy_yields"
level: 2
address: 6250
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "direct_power_consumption_today_pv"
level: 1
address: 6290
datatype: "U16"
unit: "W"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "direct_power_consumption_pv"
level: 1
address: 6386
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "direct_power_consumption_monthly_pv"
level: 2
address: 6417
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "direct_power_consumption_yearly_pv"
level: 2
address: 6429
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "export_power_from_pv_today"
level: 1
address: 6469
datatype: "U16"
unit: "W"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "export_power_from_pv"
level: 1
address: 6565
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "export_power_from_pv_monthly"
level: 2
address: 6596
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "export_power_from_pv_yearly"
level: 2
address: 6608
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_charge_power_from_pv_today"
level: 1
address: 6648
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_charge_power_from_pv"
level: 1
address: 6744
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_charge_power_from_pv_monthly"
level: 2
address: 6775
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_charge_power_from_pv_yearly"
level: 2
address: 6787
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
##### Residential Hybrid Inverters only END
- name: "string_1_current"
@@ -864,14 +916,14 @@ registers:
datatype: "U16"
accuracy: 0.01
unit: "A"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "string_2_current"
level: 2
address: 7014
datatype: "U16"
accuracy: 0.01
unit: "A"
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT"]
models: ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
- name: "string_3_current"
level: 2
address: 7015
@@ -955,7 +1007,7 @@ registers:
datatype: "U16"
accuracy: 0.01
unit: "A"
models: ["SG60KTL-M", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG80KTL-M", "SG30CX", "SG33CX", "SG36CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", ]
models: ["SG60KTL-M","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG80KTL-M","SG30CX","SG33CX","SG36CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT", ]
- name: "string_15_current"
level: 2
address: 7027
@@ -1026,10 +1078,34 @@ registers:
accuracy: 0.01
unit: "A"
models: ["SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN"]
##### Residential Hybrid Inverters only START
- name: "system_state"
level: 2
address: 13000
datatype: "U16"
datarange:
- response: 0x0002
value: "Stop"
- response: 0x0002
value: "Standby"
- response: 0x0010
value: "Initial Standby"
- response: 0x0020
value: "Startup"
- response: 0x0040
value: "Run"
- response: 0x0100
value: "Fault"
- response: 0x0400
value: "Maintain Run"
- response: 0x0800
value: "Forced Run"
- response: 0x1000
value: "Off-grid Run"
- response: 0x2501
value: "Restarting"
- response: 0x4000
value: "EMS Run"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "running_state"
level: 2
@@ -1040,59 +1116,426 @@ registers:
level: 2
address: 13002
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_pv_generation"
level: 1
address: 13003
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_pv_generation"
- name: "daily_pv_export"
level: 1
address: 13005
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_export_from_pv"
- name: "total_pv_export"
level: 1
address: 13006
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "load_power_hybrid"
level: 1
address: 13008
datatype: "S32"
accuracy: 0.1
unit: "W"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "export_power_hybrid"
level: 1
address: 13010
datatype: "S32"
unit: "W"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "daily_battery_charge_from_pv"
level: 1
address: 13012
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_battery_charge_from_pv"
level: 1
address: 13013
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "co2_reduction"
level: 2
address: 13015
datatype: "U32"
accuracy: 0.1
unit: "kg"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "daily_direct_energy_consumption"
level: 1
address: 13017
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_direct_energy_consumption"
level: 1
address: 13018
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_voltage"
level: 2
address: 13020
datatype: "U16"
accuracy: 0.1
unit: "V"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_current"
level: 2
address: 13021
datatype: "U16"
accuracy: 0.1
unit: "A"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_power"
level: 1
address: 13022
datatype: "U16"
unit: "W"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_level"
level: 1
address: 13023
datatype: "U16"
accuracy: 0.1
unit: "%"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_state_of_healthy"
level: 2
address: 13024
datatype: "U16"
accuracy: 0.1
unit: "%"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_temperature"
level: 2
address: 13025
datatype: "S16"
accuracy: 0.1
unit: "°C"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "daily_battery_discharge_energy"
level: 2
address: 13026
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_battery_discharge_energy"
level: 2
address: 13027
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "self_consumption_of_day"
level: 1
address: 13029
datatype: "U16"
accuracy: 0.1
unit: "%"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "grid_state"
level: 1
address: 13030
datatype: "U16"
datarange:
- response: 0xAA
value: "Off-grid"
- response: 0x55
value: "On-grid"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "phase_a_current"
level: 2
address: 13031
datatype: "S16"
accuracy: 0.1
unit: "A"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "phase_b_current"
level: 2
address: 13032
datatype: "S16"
accuracy: 0.1
unit: "A"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "phase_c_current"
level: 2
address: 13033
datatype: "S16"
accuracy: 0.1
unit: "A"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_active_power"
level: 0
address: 13034
datatype: "S32"
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "daily_import_energy"
level: 1
address: 13036
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_import_energy"
level: 1
address: 13037
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_capacity"
level: 1
address: 13039
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "daily_charge_energy"
level: 2
address: 13040
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_charge_energy"
level: 2
address: 13041
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "drm_state"
level: 2
address: 13043
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "daily_export_energy"
level: 1
address: 13045
datatype: "U16"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "total_export_energy"
level: 2
address: 13046
datatype: "U32"
accuracy: 0.1
unit: "kWh"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "inverter_alarm"
level: 3
address: 13050
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "grid-side_fault"
level: 3
address: 13052
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "system_fault1"
level: 3
address: 13054
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "system_fault2"
level: 3
address: 13056
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "dc-side_fault"
level: 3
address: 13058
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "permanent_fault"
level: 3
address: 13060
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bdc-side_fault"
level: 3
address: 13062
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bdc-side_permanent_fault"
level: 3
address: 13064
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_fault"
level: 3
address: 13066
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "battery_alarm"
level: 3
address: 13068
datatype: "U32"
accuracy: 0.1
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bms_alarm"
level: 3
address: 13070
datatype: "U32"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bms_protection"
level: 3
address: 13072
datatype: "U32"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bms_fault1"
level: 3
address: 13074
datatype: "U32"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bms_fault2"
level: 3
address: 13076
datatype: "U32"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bms_alarm2"
level: 3
address: 13078
datatype: "U32"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
- name: "bms_status"
level: 3
address: 13100
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "max_charging_current"
level: 3
address: 13101
datatype: "U16"
unit: "A"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "max_discharging_current"
level: 3
address: 13102
datatype: "U16"
unit: "A"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "warning"
level: 3
address: 13103
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "protection"
level: 3
address: 13104
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "fault1"
level: 3
address: 13105
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "fault2"
level: 3
address: 13106
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "soc"
level: 2
address: 13107
datatype: "U16"
unit: "%"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "soh"
level: 2
address: 13108
datatype: "U16"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "battery_current"
level: 2
address: 13109
datatype: "U16"
unit: "A"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "battery_voltage"
level: 2
address: 13110
datatype: "U16"
accuracy: 0.01
unit: "V"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "cycle_count"
level: 2
address: 13111
datatype: "U16"
accuracy: 0.01
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "average_cell_voltage"
level: 2
address: 13112
datatype: "U16"
unit: "V"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "max_cell_voltage"
level: 2
address: 13113
datatype: "U16"
unit: "V"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "min_cell_voltage"
level: 2
address: 13114
datatype: "U16"
unit: "V"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "battery_pack_voltage"
level: 2
address: 13115
datatype: "U16"
unit: "V"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "average_cell_temp"
level: 2
address: 13116
datatype: "S16"
unit: "°C"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "max_cell_temp"
level: 2
address: 13117
datatype: "S16"
unit: "°C"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
- name: "min_cell_temp"
level: 2
address: 13118
datatype: "S16"
unit: "°C"
models: ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30"]
##### Residential Hybrid Inverters only END
- hold:
- name: "year"
level: 0
@@ -1212,7 +1655,7 @@ registers:
level: 2
address: 5020
datatype: "U16"
models: ["SG33CX","SG40CX","SG50CX","SG75CX","SG110CX","SG136TX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG225HX","SG250HX","SG25CX-SA","SG100CX","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
models: ["SG33CX","SG40CX","SG50CX","SG75CX","SG110CX","SG136TX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG225HX","SG250HX","SG25CX-SA","SG100CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
datarange:
- response: 0xAA
value: "Enable"
@@ -1225,7 +1668,7 @@ registers:
level: 2
address: 5035
datatype: "U16"
models: ["SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG136TX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG225HX","SG250HX","SG25CX-SA","SG100CX","SG75CX"]
models: ["SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG125HV-20","SG33CX","SG40CX","SG50CX","SG110CX","SG136TX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG225HX","SG250HX","SG25CX-SA","SG100CX","SG75CX"]
datarange:
- response: 0xAA
value: "Enable"
@@ -1270,7 +1713,7 @@ registers:
level: 2
address: 5041
datatype: "U16"
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG125HV","SG125HV-20","SG80KTL","SG33CX","SG40CX","SG50CX","SG100CX、SG75CX","SG110CX","SG136TX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG225HX"]
models: ["SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT","SG80KTL-M","SG125HV","SG125HV-20","SG80KTL","SG33CX","SG40CX","SG50CX","SG100CX、SG75CX","SG110CX","SG136TX","SG250HX","SG30CX","SG36CX-US","SG60CX-US","SG250HX-US","SG250HX-IN","SG25CX-SA","SG225HX"]
datarange:
- response: 0xAA
value: "Enable"
@@ -1304,7 +1747,9 @@ registers:
# address: 5155-5199
scan: # these have to be 1 less than the first register
- read:
- start: 5000
- start: 4949
range: 50
- start: 5000 # We don't start at 4999 because we read register 5000 once manually, not every scan
range: 100
- start: 5100
range: 100
@@ -1338,5 +1783,6 @@ scan: # these have to be 1 less than the first register
- start: 5034
range: 10
# full Models Supported:
#["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
# Models Supported:
# PV ["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG5.0RS","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
# Hybrid ["SH5K-20","SH3K6","SH4K6","SH5K-V13","SH5K-30","SH3K6-30","SH4K6-30","SH5.0RS","SH3.6RS","SH4.6RS","SH6.0RS","SH10RT","SH8.0RT","SH6.0RT","SH5.0RT"]
+23 -20
View File
@@ -8,6 +8,7 @@ from datetime import datetime
import importlib
import logging
import logging.handlers
import sys
import getopt
import yaml
@@ -35,7 +36,7 @@ class SungrowInverter():
self.registers = [[]]
self.registers.pop() # Remove null value from list
self.registers_custom = [{'name': 'export_to_grid', 'unit': 'w'}, {'name': 'import_from_grid', 'unit': 'w'}, {'name': 'run_state'}]
self.registers_custom = [{'name': 'export_to_grid', 'unit': 'W'}, {'name': 'import_from_grid', 'unit': 'W'}, {'name': 'run_state'}]
self.register_ranges = [[]]
self.register_ranges.pop() # Remove null value from list
@@ -200,12 +201,16 @@ class SungrowInverter():
if register_type == register['type'] and register['address'] == run:
register_name = register['name']
register_value = None
# Return the 32bit value if needed
if register.get('datatype') == "U32" or register.get('datatype') == "S32":
register_value = rr.registers[num]
# Convert unsigned to signed
if register.get('datatype') == "S32":
u32_value = rr.registers[num+1]
if u32_value and register_value:
register_value = (u32_value * 65535) + register_value
if u32_value == 65535: # Flag to say value is negative for 32bit
register_value = (register_value - 65535)
elif register.get('datatype') == "S16":
if register_value >= 32767: # Anything greater than 32767 is a negative for 16bit
register_value = (register_value - 65535)
# We convert a system response to a human value
if register.get('datarange'):
@@ -215,16 +220,8 @@ class SungrowInverter():
if not register_value:
register_value = rr.registers[num]
# Adjust the value if needed
if register.get('indicator'):
indicator_value = rr.registers[num+1]
if indicator_value == 65535:
register_value = -1 * (65535 - register_value)
# If xFF (U 65535 / S 32767) then change to 0, looks better when logging / graphing
if register.get('datatype') == 'S16' and (register_value == 32767 or register_value == 65535):
register_value = 0
elif (register.get('datatype') == 'U16' or register.get('datatype') == 'S32' or register.get('datatype') == 'U32') and register_value == 65535:
# If xFF / xFFFF then change to 0, looks better when logging / graphing
if register_value == 65535:
register_value = 0
if register.get('accuracy'):
@@ -333,7 +330,7 @@ class SungrowInverter():
# to help with graphing.
try:
if self.latest_scrape.get('start_stop'):
if self.latest_scrape.get('start_stop', False) == 'Start' and self.latest_scrape.get('work_state_1', False) == 'Run':
if self.latest_scrape.get('start_stop', False) == 'Start' and self.latest_scrape.get('work_state_1', False).contains('Run'):
self.latest_scrape["run_state"] = "ON"
else:
self.latest_scrape["run_state"] = "OFF"
@@ -398,19 +395,22 @@ class SungrowInverter():
def main():
configfilename = 'config.yaml'
logfolder = ''
try:
opts, args = getopt.getopt(sys.argv[1:],"hc:v:", "runonce")
opts, args = getopt.getopt(sys.argv[1:],"hc:l:v:", "runonce")
except getopt.GetoptError:
logging.debug(f'No options passed via command line')
for opt, arg in opts:
if opt == '-h':
print(f'\nSunGather {__version__}')
print(f'\nhttps://sungather.app')
print(f'usage: python3 sungather.py [options]')
print(f'\nCommandling arguments override any config file settings')
print(f'Options and arguments:')
print(f'-c config.yaml : Specify config file.')
print(f'-l /logs/ : Specify folder to store logs.')
print(f'-v 30 : Logging Level, 10 = Debug, 20 = Info, 30 = Warning (default), 40 = Error')
print(f'--runonce : Run once then exit')
print(f'-h : print this help message and exit (also --help)')
@@ -419,6 +419,8 @@ def main():
sys.exit()
elif opt == '-c':
configfilename = arg
elif opt == '-l':
logfolder = arg
elif opt == '-v':
if arg.isnumeric():
if int(arg) >= 0 and int(arg) <= 50:
@@ -447,6 +449,7 @@ def main():
try:
registersfile = yaml.safe_load(open('registers.yaml'))
logging.info(f"Loaded registers: {os.getcwd()}/registers.yaml")
logging.info(f"Registers file version: {registersfile.get('version','UNKNOWN')}")
except Exception as err:
logging.error(f"Failed: Loading registers: {os.getcwd()}/registers.yaml {err}")
sys.exit(f"Failed: Loading registers: {os.getcwd()}/registers.yaml {err}")
@@ -474,8 +477,8 @@ def main():
if not config_inverter['log_file'] == "OFF":
if config_inverter['log_file'] == "DEBUG" or config_inverter['log_file'] == "INFO" or config_inverter['log_file'] == "WARNING" or config_inverter['log_file'] == "ERROR":
logfile = datetime.now().strftime("%Y%m%d_%H%M%S_SunGather.log")
fh = logging.FileHandler(logfile, mode='w', encoding='utf-8')
logfile = logfolder + "SunGather.log"
fh = logging.handlers.RotatingFileHandler(logfile, mode='w', encoding='utf-8', maxBytes=10485760, backupCount=10) # Log 10mb files, 10 x files = 100mb
fh.formatter = logger.handlers[0].formatter
fh.setLevel(config_inverter['log_file'])
logger.addHandler(fh)
+1 -1
View File
@@ -1 +1 @@
__version__ = '0.3.2'
__version__ = '0.3.7'
+1
View File
@@ -0,0 +1 @@
sungather.app
+6
View File
@@ -0,0 +1,6 @@
theme: jekyll-theme-cayman
plugins:
- jekyll-relative-links
relative_links:
enabled: true
collections: true
+287
View File
@@ -0,0 +1,287 @@
<div id="top"></div>
[![Contributors][contributors-shield]][contributors-url]
[![Forks][forks-shield]][forks-url]
[![Stargazers][stars-shield]][stars-url]
[![Issues][issues-shield]][issues-url]
[![GPL3 License][license-shield]][license-url]
<br />
<div align="center">
<h2 align="center">SunGather</h2>
<p align="center">
Collect data from Sungrow Inverters using ModbusTcpClient, <a href="https://github.com/rpvelloso/Sungrow-Modbus">SungrowModbusTcpClient</a> or <a href="https://github.com/bohdan-s/SungrowModbusWebClient">SungrowModbusWebClient</a> and export to various locations.
<br />
<br />
<a href="https://github.com/bohdan-s/SunGather/issues">Report Bug</a>
·
<a href="https://github.com/bohdan-s/SunGather/issues">Request Feature</a>
</p>
</div>
<!-- ABOUT THE PROJECT -->
## About The Project
<b>Join the Discord Server to discuss, suggestions or for any help: <a href="https://discord.gg/7j2MVsT5wn">SunGather Discord</a></b>
Access ModBus data from almost any network connected Sungow Inverter.
On first connection the tool will query your inverter, retrieve the model and return the correct registers for your device. No more searching registers or creating model files.
Register information based on official documentation: <a href="https://github.com/bohdan-s/Sungrow-Inverter/blob/main/Modbus%20Information/Communication%20Protocol%20of%20PV%20Grid-Connected%20String%20Inverters_V1.1.37_EN.pdf">Communication Protocol of PV Grid-Connected String Inverters</a> and <a href="https://github.com/bohdan-s/Sungrow-Inverter/blob/main/Modbus%20Information/communication-protocol-of-residential-hybrid-inverterv1.0.20-1.pdf">Communication Protocol of Residential Hybrid Inverters</a>
Has multiple export locations out of the box:
* Console - Log directly to screen
* MQTT - Load into MQTT, and optionally Home Assistance including Discovery
* PVOutput - Load into PVOutput.org
* InfluxDB - Load data directly into InfluxDB
* Simple webserver showing collected data
* Rasberry Pi Docker support
* and more coming....
I have learned a lot from the following projects, THANK YOU
* [solariot](https://github.com/meltaxa/solariot)
* [modbus4mqtt](https://github.com/tjhowse/modbus4mqtt)
* [ModbusTCP2MQTT](https://github.com/TenySmart/ModbusTCP2MQTT)
<p align="right">(<a href="#top">back to top</a>)</p>
## Raodmap / TO DO
* Full Home Assistant integration, as HACS addon
### Built With
* [Python3](https://www.python.org/)
### Requires
* [paho-mqtt>=1.5.1](https://pypi.org/project/paho-mqtt/)
* [pymodbus>=2.4.0](https://pypi.org/project/pymodbus/)
* [SungrowModbusTcpClient>=0.1.6](https://pypi.org/project/SungrowModbusTcpClient/)
* [SungrowModbusWebClient>=0.2.6](https://pypi.org/project/SungrowModbusWebClient/)
* [PyYAML>=6.0](https://pypi.org/project/PyYAML/)
* [requests>=2.26.0](https://pypi.org/project/requests/)
* [influxdb-client>=1.24.0](https://pypi.org/project/influxdb-client/)
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- GETTING STARTED -->
## Getting Started
# Local
```sh
git clone https://github.com/bohdan-s/SunGather.git
cd SunGather
pip3 install --upgrade -r requirements.txt
```
Copy config-example.py to config.py, change values as required (see comments in file)
```sh
copy config-example.py config.py
```
Run SunGather:
```sh
python3 sungather.py
```
# Docker
docker run options:
-v {path to}/config.yaml:/config/config.yaml <- Set Config File Location
-v {logpath}:/logs <- Set Log folder Location if using log to file (also set log_file in config.yaml)
-e TZ=Australia/Sydney <- Set Timezone
-p 8080:8080 <- Set Web server port (only if using the webserver export)
```sh
docker pull bohdans/sungather
docker run -d --name sungather \
--restart always \
-v {path to}/config.yaml:/config/config.yaml \
-v {logpath}:/logs \
-e TZ=Australia/Sydney \
-p 8080:8080 \
bohdans/sungather
```
Note: replace Australia/Sydney with relevant timezone
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- USAGE EXAMPLES -->
## Usage
See config-example.py it contains default options and comments.
If you want to use the new Energy section in Home Assistant, follow the Home Assistant setup below.
<p align="right">(<a href="#top">back to top</a>)</p>
### Commandline Arguments
usage: python3 sungather.py [options]
Commandline arguments override any config file settings
**-c config.yaml** - Specify config file.
**-v 30** - Logging Level, 10 = Debug, 20 = Info, 30 = Warning (default), 40 = Error
**--runonce** - Run once then exit
**-h** - print this help message and exit (also --help)
Example:
```sh
python3 sungather.py -c /full/path/config.yaml
```
## Exports
A collection of exports are available:
* console: Output information to console, useful for troubleshooting
* webserver: Output to a simple website, default http://localhost:8080 or http://\<serverip\>:8080
* mqtt: Output to a pre-existing MQTT server, needed for Home Assistant integration
* pvoutput: Output to PVOutput.org, requires account and solar is set up on website first.
* InfluxDB: Output directly to InfluxDB, can then be used by Grafana, etc..
## Registers
This tool should be able to access most registers exposed.
Set the following in config.yaml under inverters section.
* level: 1 - This is the most useful data for day to day
* Level: 2 - This should be everything your inverter supports
* Level: 3 - This will try every register, you will get lots of 0/65535 responses for registers not supported.
* smart_meter: True - Set to true if you have a smart reader installed, this will return power usage at the meter box, without it you can not calculate house power usage.
### Useful Registers:
This is just a brief list of registers I have found useful
**daily_power_yields** - Total Power in kWh generated today
**total_power_yields** - Total Power in kWh generated since inverter install
**total_running_time** - Total Hours inverter has been powered on since install
**internal_temperature** - Internal temperature of the Inverter
**total_active_power** - Current power being generated by the inverter in Watts
**meter_power** - Power usage at the meter box, needs a smart meter installed. +ve means consuming from the grid, -ve means exporting to the grid
**load_power** - Power being consumed in total
**export_to_grid** - How much being currently exported to the grid. This is calculated from meter_power if -ve value, returned as a positive value
**import_from_grid** - How much being currently imported from grid. This is calculated from meter_power if +ve value
**timestamp** - Last time data was collected, based on Inverters clock by default
<p align="right">(<a href="#top">back to top</a>)</p>
## Home Assistant setup
In the SunGather config.yaml you need to set the smart_meter if you have one;
```
smart_meter: True
```
HA sensors created by the MQTT auto-discovery;
```
sensor.inverter_active_power
sensor.inverter_daily_generation
sensor.inverter_export_to_grid
sensor.inverter_import_from_grid
sensor.inverter_load_power
sensor.inverter_meter_power
```
The Inverter reports Power (W), but HA needs Energy (Wh).
You can use a "Riemann sum integral" (called integration) to convert it.
Put the following into your sensors.yaml
```
sensor:
- platform: integration
source: sensor.inverter_active_power
name: Solar Production (Sungather)
- platform: integration
source: sensor.inverter_export_to_grid
name: Return to Grid (Sungather)
- platform: integration
source: sensor.inverter_import_from_grid
name: Grid Consumption (Sungather)
```
The additional sensors then setup in HA are the following with Wh unit of measurement for the Energy platform.
Solar Production (Sungather)
Return to Grid (Sungather)
Grid Consumption (Sungather)
Restart Home Assistant for the sensors.yaml to be loaded.
Make sure SunGather is running, wait 5 minutes for initial data to populate.
Navigate to the Energy platform (Configuration > Energy). Add these sensors to the following areas:
Electricity Grid > Grid Consumption -> Grid Consumption (Sungather)
Electricity Grid > Return to Grid -> Return to Grid (Sungather)
Solar Panels > Solar Production -> Solar Production (Sungather)
<p align="right">(<a href="#top">back to top</a>)</p>
## Tested
* SG7.0RT with WiNet-S Dongle
* SG10RT with WiNet-S Dongle and Ethernet (Credit: @rark-ha)
<p align="right">(<a href="#top">back to top</a>)</p>
## Supported
### PV Grid-Connected String Inverters
SG30KTL, SG10KTL, SG12KTL, SG15KTL, SG20KTL, SG30KU, SG36KTL, SG36KU, SG40KTL, SG40KTL-M, SG50KTL-M, SG60KTL-M, SG60KU, SG30KTL-M, SG30KTL-M-V31, SG33KTL-M, SG36KTL-M, SG33K3J, SG49K5J, SG34KJ, LP_P34KSG, SG50KTL-M-20, SG60KTL, SG80KTL, SG80KTL-20, SG60KU-M, SG5KTL-MT, SG6KTL-MT, SG8KTL-M, SG10KTL-M, SG10KTL-MT, SG12KTL-M, SG15KTL-M, SG17KTL-M, SG20KTL-M, SG80KTL-M, SG111HV, SG125HV, SG125HV-20, SG30CX, SG33CX, SG36CX-US, SG40CX, SG50CX, SG60CX-US, SG110CX, SG250HX, SG250HX-US, SG100CX, SG100CX-JP, SG250HX-IN, SG25CX-SA, SG75CX, SG3.0RT, SG4.0RT, SG5.0RT, SG6.0RT, SG7.0RT, SG8.0RT, SG10RT, SG12RT, SG15RT, SG17RT, SG20RT
### PV Grid-Connected String Inverters Gen 2
SG5K-D, SG8K-D
### Residential Hybrid Inverters
SH5K-20, SH3K6, SH4K6, SH5K-V13, SH5K-30, SH3K6-30, SH4K6-30, SH5.0RS, SH3.6RS, SH4.6RS, SH6.0RS, SH10RT, SH8.0RT, SH6.0RT, SH5.0RT
<p align="right">(<a href="#top">back to top</a>)</p>
## Building
Multi Arch (BuildX) Including Raspberry Pi
```sh
docker run --privileged --rm tonistiigi/binfmt --install all
docker buildx create --platform linux/amd64,linux/arm64/v8 --use
docker buildx build --push --platform linux/amd64,linux/arm64/v8 -t bohdans/sungather:latest -t bohdans/sungather:v<version> .
```
Current Arch (docker build)
```sh
docker build --no-cache --rm -t bohdans/sungather:latest -t bohdans/sungather:v<version> .
docker push bohdans/sungather -a
```
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- LICENSE -->
## License
Distributed under the GPL3 License. See `LICENSE.txt` for more information.
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- CONTACT -->
## Contact
Project Link: [https://github.com/bohdan-s/SungrowModbusWebClient](https://github.com/bohdan-s/SungrowModbusWebClient)
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- ACKNOWLEDGMENTS -->
## Acknowledgments
* [solariot](https://github.com/meltaxa/solariot)
* [modbus4mqtt](https://github.com/tjhowse/modbus4mqtt)
* [ModbusTCP2MQTT](https://github.com/TenySmart/ModbusTCP2MQTT)
<p align="right">(<a href="#top">back to top</a>)</p>
<!-- MARKDOWN LINKS & IMAGES -->
<!-- https://www.markdownguide.org/basic-syntax/#reference-style-links -->
[contributors-shield]: https://img.shields.io/github/contributors/bohdan-s/SunGather.svg?style=for-the-badge
[contributors-url]: https://github.com/bohdan-s/SunGather/graphs/contributors
[forks-shield]: https://img.shields.io/github/forks/bohdan-s/SunGather.svg?style=for-the-badge
[forks-url]: https://github.com/bohdan-s/SunGather/network/members
[stars-shield]: https://img.shields.io/github/stars/bohdan-s/SunGather.svg?style=for-the-badge
[stars-url]: https://github.com/bohdan-s/SunGather/stargazers
[issues-shield]: https://img.shields.io/github/issues/bohdan-s/SunGather.svg?style=for-the-badge
[issues-url]: https://github.com/bohdan-s/SunGather/issues
[license-shield]: https://img.shields.io/github/license/bohdan-s/SunGather.svg?style=for-the-badge
[license-url]: https://github.com/bohdan-s/SunGather/blob/main/LICENSE.txt
+1 -1
View File
@@ -3,5 +3,5 @@ requests>=2.26.0
paho-mqtt>=1.5.1
pymodbus>=2.5.3
SungrowModbusTcpClient>=0.1.5
SungrowModbusWebClient>=0.2.7
SungrowModbusWebClient>=0.3.2
influxdb-client>=1.24.0