mirror of
https://github.com/alexhopeoconnor/SunGather.git
synced 2026-10-22 10:42:09 +10:00
v0.2.0, Improved register detection, improved performance, MQTT and PVOutput rewrites
This commit is contained in:
@@ -1,41 +1,43 @@
|
|||||||
inverter:
|
inverter:
|
||||||
host: 192.168.1.100 # [Required] IP Address of the Inverter or Dongle
|
host: 192.168.1.100 # [Required] IP Address of the Inverter or Dongle
|
||||||
# port: 502 # [Optional] Default for modbus is 502, for http is 8082
|
# port: 502 # [Optional] Default for modbus is 502, for http is 8082
|
||||||
# slave: 0x01 # [Optional] Default is 0x01
|
# slave: 0x01 # [Optional] Default is 0x01
|
||||||
# timeout: 10 # [Optional] Default is 10
|
# timeout: 10 # [Optional] Default is 10
|
||||||
# scan_interval: 30 # [Optional] Default is 30
|
# scan_interval: 30 # [Optional] Default is 30
|
||||||
connection: sungrow # [Required] options: modbus, sungrow, http
|
connection: sungrow # [Required] options: modbus, sungrow, http
|
||||||
# model: "SG7.0RT" # [Optional] This is autodetected on startup, only needed if detection issues or for testing
|
# model: "SG7.0RT" # [Optional] This is autodetected on startup, only needed if detection issues or for testing
|
||||||
# See model list here: https://github.com/bohdan-s/SunGather#supported
|
# See model list here: https://github.com/bohdan-s/SunGather#supported
|
||||||
# smart_meter: True # [Optional] Default is False, Set to true if inverter supports reading grind / house consumption
|
# smart_meter: True # [Optional] Default is False, Set to true if inverter supports reading grind / house consumption
|
||||||
# use_local_time: False # [Optional] Default False, Uses Inventer time, if try uses PC time when updating timestamps (e.g. PVOutput)
|
# use_local_time: False # [Optional] Default False, Uses Inventer time, if try uses PC time when updating timestamps (e.g. PVOutput)
|
||||||
# hybrid: False # [Optional] Default false, if you have a Hybrid (battery) set to True
|
# manual_load: False # [Optional] Manually calculate load total_active_power + meter_power if the inverter does not supply it
|
||||||
# manual_load: False # [Optional] Manually calculate load total_active_power + meter_power if the inverter does not supply it
|
# logging: 30 # [Optional] 10 = Debug, 20 = Info, 30 = Warning (default), 40 = Error
|
||||||
# logging: 30 # [Optional] 10 = Debug, 20 = Info, 30 = Warning (default), 40 = Error
|
# level: 1 # [Optional] Set the amount of information to gather
|
||||||
# level: 1 # [Optional] Set the amount of information to gather
|
# 0 = Model and Solar Generation,
|
||||||
# 0 = Model and Solar Generation,
|
# 1 (default) = Useful data, all required for exports,
|
||||||
# 1 (default) = Useful data, all required for exports,
|
# 2 everything your Inverter supports,
|
||||||
# 2 everything your Inverter supports,
|
# 3 Everything from every register
|
||||||
# 3 Everything from every register
|
|
||||||
|
|
||||||
|
# If you do not want to use a export, you can either remove the whole configuration block
|
||||||
|
# or set enabled: False
|
||||||
exports:
|
exports:
|
||||||
# Print Registers to console, good for debugging / troubleshooting
|
# Print Registers to console, good for debugging / troubleshooting
|
||||||
- name: console
|
- name: console
|
||||||
enabled: False
|
enabled: False # [Optional] Default is False
|
||||||
|
|
||||||
# Runs a simple Webserver showing Config and last read registers
|
# Runs a simple Webserver showing Config and last read registers
|
||||||
- name: http
|
# Access at http://localhost:8080 or http://[serverip]:8080
|
||||||
enabled: True # Access at http://localhost:8080 or http://[serverip]:8080
|
- name: webserver
|
||||||
# port: 8080 # Default port is 8080
|
enabled: True # [Optional] Default is False
|
||||||
|
# port: 8080 # [Optional] Default is 8080
|
||||||
|
|
||||||
# Output data to InfluxDB
|
# Output data to InfluxDB
|
||||||
- name: influxdb
|
- name: influxdb
|
||||||
enabled: False
|
enabled: False # [Optional] Default is False
|
||||||
token: "xxx" # [Required] API Token
|
token: "xxx" # [Required] API Token
|
||||||
url: "http://localhost:8086" # [Optional] Default URL is http://localhost:8086
|
url: "http://localhost:8086" # [Optional] Default URL is http://localhost:8086
|
||||||
org: "Default" # [Required] InfluxDB Organization
|
org: "Default" # [Required] InfluxDB Organization
|
||||||
bucket: "SunGather" # [Required] InfluxDB Bucket
|
bucket: "SunGather" # [Required] InfluxDB Bucket
|
||||||
measurements:
|
measurements: # [Required] Registers to publish to bucket
|
||||||
- point: "power"
|
- point: "power"
|
||||||
register: daily_power_yields
|
register: daily_power_yields
|
||||||
- point: "power"
|
- point: "power"
|
||||||
@@ -51,88 +53,104 @@ exports:
|
|||||||
- point: "temp"
|
- point: "temp"
|
||||||
register: internal_temperature
|
register: internal_temperature
|
||||||
|
|
||||||
|
|
||||||
# Publish Registers to MQTT / Home Assistant
|
# Publish Registers to MQTT / Home Assistant
|
||||||
- name: mqtt
|
- name: mqtt
|
||||||
host: 192.168.1.200
|
enabled: False # [Optional] Default is False
|
||||||
# port: 1883
|
host: 192.168.1.200 # [Required] IP or Hostname of MQTT Server
|
||||||
topic: "tele/inverter_{model}/SENSOR" # Variable {model} will be replaced with model number
|
# port: 1883 # [Optional] Default 1883
|
||||||
# username:
|
# topic: "tele/inverter_{model}/SENSOR" # [Optional] Default: "tele/inverter_{model}/SENSOR", Variable {model} will be replaced with model number of inverter
|
||||||
# password:
|
# username: # [Optional] Username is MQTT server requires it
|
||||||
ha_discovery: True # Home Assistant Discovery, False by default
|
# password: # [Optional] Password is MQTT server requires it
|
||||||
ha_topics: # Name in HA, from Register
|
ha_discovery: True # [Optional] Default False, Home Assistant Discovery
|
||||||
|
ha_topics: # [Optional] / [Required] ha_discovery: True, Topics to enable discovery for HA
|
||||||
- name: "Daily Generation"
|
- name: "Daily Generation"
|
||||||
|
sensor_type: sensor
|
||||||
register: daily_power_yields
|
register: daily_power_yields
|
||||||
unit: kWh
|
unit: kWh
|
||||||
dev_class: energy
|
dev_class: energy
|
||||||
state_class: total_increasing
|
state_class: total_increasing
|
||||||
- name: "Active Power"
|
- name: "Active Power"
|
||||||
|
sensor_type: sensor
|
||||||
register: total_active_power
|
register: total_active_power
|
||||||
unit: W
|
unit: W
|
||||||
dev_class: power
|
dev_class: power
|
||||||
state_class: measurement
|
state_class: measurement
|
||||||
- name: "Load Power"
|
- name: "Load Power"
|
||||||
|
sensor_type: sensor
|
||||||
register: load_power
|
register: load_power
|
||||||
unit: W
|
unit: W
|
||||||
dev_class: power
|
dev_class: power
|
||||||
state_class: measurement
|
state_class: measurement
|
||||||
- name: "Meter Power"
|
- name: "Meter Power"
|
||||||
|
sensor_type: sensor
|
||||||
register: meter_power
|
register: meter_power
|
||||||
unit: W
|
unit: W
|
||||||
dev_class: power
|
dev_class: power
|
||||||
state_class: measurement
|
state_class: measurement
|
||||||
- name: "Export to Grid"
|
- name: "Export to Grid"
|
||||||
|
sensor_type: sensor
|
||||||
register: export_to_grid
|
register: export_to_grid
|
||||||
unit: W
|
unit: W
|
||||||
dev_class: power
|
dev_class: power
|
||||||
state_class: measurement
|
state_class: measurement
|
||||||
- name: "Import from Grid"
|
- name: "Import from Grid"
|
||||||
|
sensor_type: sensor
|
||||||
register: import_from_grid
|
register: import_from_grid
|
||||||
unit: W
|
unit: W
|
||||||
dev_class: power
|
dev_class: power
|
||||||
state_class: measurement
|
state_class: measurement
|
||||||
- name: "Temperature"
|
- name: "Temperature"
|
||||||
|
sensor_type: sensor
|
||||||
register: internal_temperature
|
register: internal_temperature
|
||||||
unit: °C
|
unit: °C
|
||||||
dev_class: temperature
|
dev_class: temperature
|
||||||
state_class: measurement
|
state_class: measurement
|
||||||
|
- name: "Power State"
|
||||||
|
sensor_type: binary_sensor
|
||||||
|
register: start_stop
|
||||||
|
dev_class: running
|
||||||
|
payload_on: "Start"
|
||||||
|
payload_off: "Stop"
|
||||||
|
|
||||||
- name: pvoutput # Publish Registers to PVOutput
|
# Publish Registers to PVOutput
|
||||||
api: "xxxxx"
|
- name: pvoutput
|
||||||
sid: "xxxxx"
|
enabled: False # [Optional] Default is False
|
||||||
# 60 for regular accounts, 300 for donation accounts
|
api: "xxxxx" # [Required] API Key, Settings > API Key
|
||||||
rate_limit: 60
|
sid: "xxxxx" # [Optional] System ID, Settings > Registered Systems > System ID
|
||||||
enabled: True
|
rate_limit: 60 # [Optional] Default 60, 60 for regular accounts, 300 for donation accounts
|
||||||
parameters:
|
status_interval: 5 # [Optional] Default 5, In minutes, options are 5 ,10,15 minute intervals: https://pvoutput.org/help/live_data.html
|
||||||
- name: v1 # Energy Generation
|
batch_points: 1 # [Optional] Default 1, how many data points to batch upload,
|
||||||
register: daily_power_yields # Solar Generated Today (Energy)
|
# Time between uploads will be status_interval * batch_points. e.g. status_invterval of 5min, and batch_points of 12 will upload to PVOutput Hourly (5 * 12 = 60 mins)
|
||||||
|
parameters: # [Required] v1 & v3 or v2 & v4 minimum. See: https://pvoutput.org/help/api_specification.html#power-and-energy-calculation
|
||||||
|
- name: v1 # Energy Generation
|
||||||
|
register: daily_power_yields # Solar Generated Today (Energy)
|
||||||
multiple: 1000
|
multiple: 1000
|
||||||
- name: v2 # Power Generation
|
- name: v2 # Power Generation
|
||||||
register: total_active_power # Current Generation (Power)
|
register: total_active_power # Current Generation (Power)
|
||||||
# - name: v3 # Energy Consumption
|
# - name: v3 # Energy Consumption
|
||||||
# register:
|
# register:
|
||||||
- name: v4 # Power Consumption
|
- name: v4 # Power Consumption
|
||||||
register: load_power # Current Home usage (Power)
|
register: load_power # Current Home usage (Power)
|
||||||
- name: v5 # Temperature
|
- name: v5 # Temperature
|
||||||
register: internal_temperature # Inverter internal temperature
|
register: internal_temperature # Inverter internal temperature
|
||||||
# - name: v6 # Voltage
|
# - name: v6 # Voltage
|
||||||
# register: total_active_power
|
# register: total_active_power
|
||||||
- name: c1 # Cumulative Flag,
|
- name: c1 # Cumulative Flag,
|
||||||
value: 1 # If using v2/v4 set to 1
|
value: 1 # If using v2/v4 set to 1
|
||||||
# - name: "n" # Net Flag
|
# - name: "n" # Net Flag
|
||||||
# value: 1
|
# value: 1
|
||||||
# - name: "v7" # Extended Value v7 - Donation Only
|
# - name: "v7" # Extended Value v7 - Donation Only
|
||||||
# register:
|
# register:
|
||||||
# - name: "v8" # Extended Value v8 - Donation Only
|
# - name: "v8" # Extended Value v8 - Donation Only
|
||||||
# register:
|
# register:
|
||||||
# - name: "v9" # Extended Value v9 - Donation Only
|
# - name: "v9" # Extended Value v9 - Donation Only
|
||||||
# register:
|
# register:
|
||||||
# - name: "v10" # Extended Value v10 - Donation Only
|
# - name: "v10" # Extended Value v10 - Donation Only
|
||||||
# register:
|
# register:
|
||||||
# - name: "v11" # Extended Value v11 - Donation Only
|
# - name: "v11" # Extended Value v11 - Donation Only
|
||||||
# register:
|
# register:
|
||||||
# - name: "v12" # Extended Value v12 - Donation Only
|
# - name: "v12" # Extended Value v12 - Donation Only
|
||||||
# register:
|
# register:
|
||||||
# - name: "m1" # Text Message 1 - Donation Only
|
# - name: "m1" # Text Message 1 - Donation Only
|
||||||
# register:
|
# register:
|
||||||
|
|
||||||
@@ -4,9 +4,12 @@ class export_console(object):
|
|||||||
def __init__(self):
|
def __init__(self):
|
||||||
return
|
return
|
||||||
|
|
||||||
# Configure MQTT
|
# Configure Console
|
||||||
def configure(self, config, config_inverter):
|
def configure(self, config, config_inverter):
|
||||||
logging.info("Configured Console Logging")
|
logging.info("Console: Configured")
|
||||||
|
print("{:<20} {:<25}".format('Config','Value'))
|
||||||
|
for setting in config_inverter:
|
||||||
|
print("{:<40} {:<25}".format(setting,str(config_inverter.get(setting))))
|
||||||
|
|
||||||
def publish(self, inverter):
|
def publish(self, inverter):
|
||||||
|
|
||||||
|
|||||||
@@ -1,4 +1,3 @@
|
|||||||
from typing import Sequence
|
|
||||||
import influxdb_client
|
import influxdb_client
|
||||||
import logging
|
import logging
|
||||||
from influxdb_client.client.write_api import SYNCHRONOUS
|
from influxdb_client.client.write_api import SYNCHRONOUS
|
||||||
@@ -27,16 +26,16 @@ class export_influxdb(object):
|
|||||||
self.measurements.append(measurement)
|
self.measurements.append(measurement)
|
||||||
|
|
||||||
self.write_api = self.client.write_api(write_options=SYNCHRONOUS)
|
self.write_api = self.client.write_api(write_options=SYNCHRONOUS)
|
||||||
logging.info(f"Configured InfluxDB Client: {self.client.url}")
|
logging.info(f"InfluxDB: Configured: {self.client.url}")
|
||||||
|
|
||||||
def publish(self, inverter):
|
def publish(self, inverter):
|
||||||
sequence = []
|
sequence = []
|
||||||
for measurement in self.measurements:
|
for measurement in self.measurements:
|
||||||
sequence.append(f"{measurement.get('point')},inverter={inverter.get('device_type_code', 'unknown').replace('.','').replace('-','')} {measurement.get('register')}={inverter.get(measurement.get('register'))}")
|
sequence.append(f"{measurement.get('point')},inverter={inverter.get('device_type_code', 'unknown').replace('.','').replace('-','')} {measurement.get('register')}={inverter.get(measurement.get('register'))}")
|
||||||
logging.info(f'InfluxDB Write: {sequence}')
|
logging.debug(f'InfluxDB: Sequence; {sequence}')
|
||||||
try:
|
try:
|
||||||
self.write_api.write(self.bucket, self.client.org, sequence)
|
self.write_api.write(self.bucket, self.client.org, sequence)
|
||||||
except Exception as err:
|
except Exception as err:
|
||||||
logging.error(err)
|
logging.error("InfluxDB: " + str(err))
|
||||||
|
|
||||||
logging.info("Published to InfluxDB")
|
logging.info("InfluxDB: Published")
|
||||||
+53
-27
@@ -6,9 +6,12 @@ class export_mqtt(object):
|
|||||||
def __init__(self):
|
def __init__(self):
|
||||||
self.mqtt_client = None
|
self.mqtt_client = None
|
||||||
self.sensor_topic = None
|
self.sensor_topic = None
|
||||||
self.ha_discovery = False
|
self.homeassistant = False
|
||||||
self.ha_topics = []
|
self.ha_discovery = True
|
||||||
self.update_model = True
|
self.ha_sensors = []
|
||||||
|
self.model = None
|
||||||
|
self.model_clean = None
|
||||||
|
self.inverter_ip = None
|
||||||
|
|
||||||
# Configure MQTT
|
# Configure MQTT
|
||||||
def configure(self, config, config_inverter):
|
def configure(self, config, config_inverter):
|
||||||
@@ -22,43 +25,66 @@ class export_mqtt(object):
|
|||||||
|
|
||||||
self.mqtt_client.connect(config.get('host'), port=config.get('port', 1883))
|
self.mqtt_client.connect(config.get('host'), port=config.get('port', 1883))
|
||||||
|
|
||||||
self.sensor_topic = config.get('topic', 'tele/inverter_{model}/SENSOR')
|
self.inverter_ip = config_inverter.get('host')
|
||||||
self.ha_discovery = config.get('ha_discovery', False)
|
|
||||||
|
|
||||||
if self.ha_discovery:
|
self.sensor_topic = config.get('topic', 'inverter/{model}/registers')
|
||||||
for ha_topic in config.get('ha_topics'):
|
self.homeassistant = config.get('homeassistant', False)
|
||||||
self.ha_topics.append(ha_topic)
|
|
||||||
|
|
||||||
logging.info(f"Configured MQTT Client: {config.get('host')}:{config.get('port', 1883)}")
|
if self.homeassistant:
|
||||||
|
for ha_sensor in config.get('ha_sensors'):
|
||||||
|
self.ha_sensors.append(ha_sensor)
|
||||||
|
|
||||||
|
logging.info(f"MQTT: Configured {config.get('host')}:{config.get('port', 1883)}")
|
||||||
|
|
||||||
def publish(self, inverter):
|
def publish(self, inverter):
|
||||||
global mqtt_client
|
global mqtt_client
|
||||||
|
|
||||||
if (self.update_model):
|
|
||||||
self.sensor_topic = self.sensor_topic.replace('{model}', inverter.get('device_type_code', 'unknown').replace('.','').replace('-',''))
|
|
||||||
self.update_model = False
|
|
||||||
|
|
||||||
if self.ha_discovery:
|
|
||||||
self.mqtt_client.reconnect()
|
|
||||||
logging.info("Publishing Home Assistant Discovery messages")
|
|
||||||
discovery_topic = 'homeassistant/sensor/inverter/{}/config'
|
|
||||||
discovery_payload = '{{"name":"Inverter {}", "uniq_id":"{}", "stat_t":"{}", "json_attr_t":"{}", "unit_of_meas":"{}", "dev_cla":"{}", "state_class":"{}", "val_tpl":"{{{{ value_json.{} }}}}", "ic":"mdi:solar-power", "device":{{ "name":"Solar Inverter", "mf":"Sungrow", "mdl":"{}", "connections":[["address", "' + self.mqtt_client._host + '" ]]}}}}'
|
|
||||||
|
|
||||||
for ha_topic in self.ha_topics:
|
|
||||||
msg = discovery_payload.format( ha_topic.get('name'), "inverter_" + ha_topic.get('name').lower().replace(' ','_'), self.sensor_topic, self.sensor_topic, ha_topic.get('unit'), ha_topic.get('dev_class'), ha_topic.get('state_class'), ha_topic.get('register'), inverter.get('device_type_code', 'unknown').replace('.',''))
|
|
||||||
result = self.mqtt_client.publish(discovery_topic.format(ha_topic.get('name').lower().replace(' ','_')), msg, retain=True)
|
|
||||||
result.wait_for_publish()
|
|
||||||
self.ha_discovery = False
|
|
||||||
|
|
||||||
# After a while you'll need to reconnect, so just reconnect before each publish
|
# After a while you'll need to reconnect, so just reconnect before each publish
|
||||||
self.mqtt_client.reconnect()
|
self.mqtt_client.reconnect()
|
||||||
|
|
||||||
|
if not self.model:
|
||||||
|
self.model = inverter.get('device_type_code', 'unknown')
|
||||||
|
self.model_clean = self.model.replace('.','').replace('-','')
|
||||||
|
self.sensor_topic = self.sensor_topic.replace('{model}', self.model_clean)
|
||||||
|
|
||||||
|
logging.debug(f'MQTT: Sensor Topic = {self.sensor_topic}')
|
||||||
|
|
||||||
|
logging.debug(f"MQTT: Publishing: {self.sensor_topic} : {json.dumps(inverter)}")
|
||||||
result = self.mqtt_client.publish(self.sensor_topic, json.dumps(inverter).replace('"', '\"'))
|
result = self.mqtt_client.publish(self.sensor_topic, json.dumps(inverter).replace('"', '\"'))
|
||||||
result.wait_for_publish()
|
result.wait_for_publish()
|
||||||
|
|
||||||
|
if self.homeassistant:
|
||||||
|
if self.ha_discovery:
|
||||||
|
for ha_sensor in self.ha_sensors:
|
||||||
|
config_msg = {}
|
||||||
|
if ha_sensor.get('name'):
|
||||||
|
ha_topic = 'homeassistant/' + ha_sensor.get('sensor_type', 'sensor') + '/inverter/' + ha_sensor.get('name').lower().replace(' ','_') + '/config'
|
||||||
|
config_msg['name'] = "Inverter " + ha_sensor.get('name')
|
||||||
|
config_msg['unique_id'] = "inverter_" + ha_sensor.get('name').lower().replace(' ','_')
|
||||||
|
config_msg['state_topic'] = self.sensor_topic
|
||||||
|
config_msg['value_template'] = "{{ value_json." + ha_sensor.get('register') + " }}"
|
||||||
|
if ha_sensor.get('unit'):
|
||||||
|
config_msg['unit_of_measurement'] = ha_sensor.get('unit')
|
||||||
|
if ha_sensor.get('dev_class'):
|
||||||
|
config_msg['device_class'] = ha_sensor.get('dev_class')
|
||||||
|
if ha_sensor.get('state_class'):
|
||||||
|
config_msg['state_class'] = ha_sensor.get('state_class')
|
||||||
|
if ha_sensor.get('payload_on'):
|
||||||
|
config_msg['payload_on'] = ha_sensor.get('payload_on')
|
||||||
|
if ha_sensor.get('payload_off'):
|
||||||
|
config_msg['payload_off'] = ha_sensor.get('payload_off')
|
||||||
|
config_msg['ic'] = "mdi:solar-power"
|
||||||
|
config_msg['device'] = { "name":"Solar Inverter", "mf":"Sungrow", "mdl":self.model, "connections":[["address", self.inverter_ip ]]}
|
||||||
|
|
||||||
|
result = self.mqtt_client.publish(ha_topic, json.dumps(config_msg), retain=True)
|
||||||
|
result.wait_for_publish()
|
||||||
|
logging.info("MQTT: Published Home Assistant Discovery messages")
|
||||||
|
self.ha_discovery = False
|
||||||
|
|
||||||
if result.rc != mqtt.MQTT_ERR_SUCCESS:
|
if result.rc != mqtt.MQTT_ERR_SUCCESS:
|
||||||
# See https://github.com/eclipse/paho.mqtt.python/blob/master/src/paho/mqtt/client.py#L149 for error code mapping
|
# See https://github.com/eclipse/paho.mqtt.python/blob/master/src/paho/mqtt/client.py#L149 for error code mapping
|
||||||
logging.error(f"Failed to publish to MQTT with error code: {result.rc}")
|
logging.error(f"MQTT: Failed to publish with error code: {result.rc}")
|
||||||
else:
|
else:
|
||||||
logging.info("Published to MQTT")
|
logging.info("MQTT: Published")
|
||||||
|
|
||||||
return result
|
return result
|
||||||
@@ -7,8 +7,7 @@ class export_pvoutput(object):
|
|||||||
def __init__(self):
|
def __init__(self):
|
||||||
self.api_key = None
|
self.api_key = None
|
||||||
self.system_id = None
|
self.system_id = None
|
||||||
self.status_url = "https://pvoutput.org/service/r2/addstatus.jsp"
|
self.statusbatch_url = "https://pvoutput.org/service/r2/addbatchstatus.jsp"
|
||||||
self.metric_mappings = None
|
|
||||||
self.rate_limit = None
|
self.rate_limit = None
|
||||||
self.parameters = []
|
self.parameters = []
|
||||||
self.latest_run = None
|
self.latest_run = None
|
||||||
@@ -26,13 +25,22 @@ class export_pvoutput(object):
|
|||||||
self.api_key = config.get('api')
|
self.api_key = config.get('api')
|
||||||
self.system_id = config.get('sid')
|
self.system_id = config.get('sid')
|
||||||
self.rate_limit = config.get('rate_limit', 60)
|
self.rate_limit = config.get('rate_limit', 60)
|
||||||
|
self.status_interval = config.get('status_interval',5)
|
||||||
|
self.batch_points = config.get('batch_points',1)
|
||||||
|
self.inverter_data = { "v1": 0, "v2": 0, "v3": 0, "v4": 0, "v5": 0, "v6": 0, "v7": 0, "v8": 0, "v9": 0, "v10": 0, "v11": 0, "v12": 0 }
|
||||||
|
self.inverter_data_count = 0
|
||||||
|
self.payload_data = None
|
||||||
|
self.batch_count = 0
|
||||||
|
self.payload_format = "{date},{time},{v1},{v2},{v3},{v4},{v5},{v6},{v7},{v8},{v9},{v10},{v11},{v12}"
|
||||||
|
|
||||||
for parameter in config.get('parameters'):
|
for parameter in config.get('parameters'):
|
||||||
self.parameters.append(parameter)
|
self.parameters.append(parameter)
|
||||||
|
|
||||||
logging.info("Configured PVOutput Client")
|
if not (self.status_interval == 5 or self.status_interval == 10 or self.status_interval == 15):
|
||||||
|
logging.warning("Status Invterval is invalid, valid options are 5, 10 and 15 minutes")
|
||||||
|
return False
|
||||||
|
|
||||||
|
logging.info("PVOutput: Configured")
|
||||||
|
|
||||||
def publish(self, inverter):
|
def publish(self, inverter):
|
||||||
"""
|
"""
|
||||||
@@ -61,44 +69,65 @@ class export_pvoutput(object):
|
|||||||
v12 Extended Value v12 No number User Defined Yes
|
v12 Extended Value v12 No number User Defined Yes
|
||||||
m1 Text Message 1 No text 30 chars max Yes
|
m1 Text Message 1 No text 30 chars max Yes
|
||||||
"""
|
"""
|
||||||
at_least_one_of = set(["v1", "v2", "v3", "v4"])
|
|
||||||
|
|
||||||
now = datetime.datetime.strptime(inverter.get('timestamp'), "%Y-%m-%d %H:%M:%S")
|
now = datetime.datetime.strptime(inverter.get('timestamp'), "%Y-%m-%d %H:%M:%S")
|
||||||
|
if not self.latest_run: # Set last run to 1 min ago if never run, that way we don't miss any uploads
|
||||||
|
self.latest_run = now - datetime.timedelta(minutes=1)
|
||||||
|
|
||||||
if self.latest_run:
|
# Add new data to old data and increase count of data points
|
||||||
# Spread out our publishes over the hour based on the rate limit
|
|
||||||
time_diff = (now - self.latest_run).total_seconds()
|
|
||||||
if time_diff < (3600 / self.rate_limit):
|
|
||||||
return "skipped"
|
|
||||||
|
|
||||||
payload = {
|
|
||||||
"d": now.strftime("%Y%m%d"),
|
|
||||||
"t": now.strftime("%H:%M"),
|
|
||||||
}
|
|
||||||
|
|
||||||
value_present = False
|
|
||||||
for parameter in self.parameters:
|
for parameter in self.parameters:
|
||||||
if parameter.get('name') == 'v1' or parameter.get('name') == 'v2' or parameter.get('name') == 'v3' or parameter.get('name') == 'v4':
|
if parameter.get('name')[0] == 'v':
|
||||||
value_present = True
|
if inverter.get(parameter.get('register')):
|
||||||
if parameter.get('register'):
|
if parameter.get('multiple'):
|
||||||
if parameter.get('multiple'):
|
self.inverter_data[parameter.get('name')] = round(self.inverter_data[parameter.get('name')] + (inverter.get(parameter.get('register')) * parameter.get('multiple')),3)
|
||||||
payload.update({parameter.get('name'): str(inverter.get(parameter.get('register')) * parameter.get('multiple'))})
|
else:
|
||||||
|
self.inverter_data[parameter.get('name')] = round(self.inverter_data[parameter.get('name')] + inverter.get(parameter.get('register')),3)
|
||||||
else:
|
else:
|
||||||
payload.update({parameter.get('name'): str(inverter.get(parameter.get('register')))})
|
logging.warning(f"PVOutput: {parameter.get('name')} configured to use {parameter.get('register')} but inverter is not returning this register")
|
||||||
elif parameter.get('value'):
|
elif parameter.get('name') == 'c1':
|
||||||
payload.update({parameter.get('name'): parameter.get('value')})
|
c1 = parameter.get('value')
|
||||||
|
self.inverter_data_count +=1
|
||||||
|
logging.info('PVOutput: Data logged')
|
||||||
|
logging.debug(f'PVOutput: Points: {self.batch_count} Data: {self.inverter_data}, c1={str(c1)}')
|
||||||
|
|
||||||
if not value_present:
|
# Process data points every status_interval
|
||||||
logging.error("PVOutput mapping failed, please review metric names and update")
|
if int(now.strftime("%M")) % self.status_interval == 0 and not now.strftime("%H:%M") == self.latest_run.strftime("%H:%M"):
|
||||||
return False
|
for v in self.inverter_data:
|
||||||
|
if not self.inverter_data[v] == 0:
|
||||||
|
self.inverter_data[v] = round(self.inverter_data[v] / self.inverter_data_count, 2)
|
||||||
|
self.inverter_data_count = 0
|
||||||
|
|
||||||
logging.debug("PVOutput Request: " + self.status_url + ", " + str(self.headers) + " : " + str(payload))
|
payload = self.payload_format
|
||||||
response = requests.post(url=self.status_url, headers=self.headers, params=payload)
|
payload = payload.replace('{date}',now.strftime("%Y%m%d"))
|
||||||
|
payload = payload.replace('{time}',now.strftime("%H:%M"))
|
||||||
|
|
||||||
if response.status_code != requests.codes.ok:
|
for data in self.inverter_data:
|
||||||
raise RuntimeError(response.text)
|
payload = payload.replace('{' + data + '}',str(self.inverter_data.get(data)))
|
||||||
|
|
||||||
|
self.inverter_data = { "v1": 0, "v2": 0, "v3": 0, "v4": 0, "v5": 0, "v6": 0, "v7": 0, "v8": 0, "v9": 0, "v10": 0, "v11": 0, "v12": 0 }
|
||||||
|
|
||||||
|
if self.payload_data:
|
||||||
|
self.payload_data = self.payload_data + ";"
|
||||||
|
else:
|
||||||
|
self.payload_data = ""
|
||||||
|
self.payload_data = self.payload_data + payload
|
||||||
|
|
||||||
|
self.batch_count +=1
|
||||||
|
|
||||||
|
if self.batch_count == self.batch_points:
|
||||||
|
payload = {'data': self.payload_data, 'c1': str(c1)}
|
||||||
|
logging.debug("PVOutput: Request; " + self.statusbatch_url + ", " + str(self.headers) + " : " + str(payload))
|
||||||
|
response = requests.post(url=self.statusbatch_url, headers=self.headers, params=payload)
|
||||||
|
self.batch_count = 0
|
||||||
|
|
||||||
|
if response.status_code != requests.codes.ok:
|
||||||
|
raise RuntimeError(response.text)
|
||||||
|
else:
|
||||||
|
self.payload_data = None
|
||||||
|
logging.info("PVOutput: Data uploaded")
|
||||||
|
else:
|
||||||
|
logging.info("PVOutput: Data added to next batch upload")
|
||||||
|
|
||||||
logging.info("Published to PVOutput")
|
|
||||||
self.latest_run = now
|
self.latest_run = now
|
||||||
|
|
||||||
|
|
||||||
|
|||||||
@@ -5,30 +5,30 @@ from version import __version__
|
|||||||
|
|
||||||
import logging
|
import logging
|
||||||
|
|
||||||
class export_http(object):
|
class export_webserver(object):
|
||||||
html_body = "Pending Data Retrieval"
|
html_body = "Pending Data Retrieval"
|
||||||
def __init__(self):
|
def __init__(self):
|
||||||
return
|
return
|
||||||
|
|
||||||
# Configure HTTP
|
# Configure Webserver
|
||||||
def configure(self, config, config_inverter):
|
def configure(self, config, config_inverter):
|
||||||
self.webServer = HTTPServer(('', config.get('port',8080)), MyServer)
|
self.webServer = HTTPServer(('', config.get('port',8080)), MyServer)
|
||||||
t = Thread(target=self.webServer.serve_forever)
|
self.t = Thread(target=self.webServer.serve_forever)
|
||||||
t.start()
|
self.t.start()
|
||||||
self.config_inverter = config_inverter
|
self.config_inverter = config_inverter
|
||||||
logging.info("Configured Simple HTTP Server")
|
logging.info(f"Webserver: Configured")
|
||||||
|
|
||||||
def publish(self, inverter):
|
def publish(self, inverter):
|
||||||
body = "<h3>Sungather v" + __version__ + "</h3></p><table><tr><th>Register</th><th>Value</th>"
|
body = "<h3>Sungather v" + __version__ + "</h3></p><table><tr><th>Register</th><th>Value</th>"
|
||||||
for register in inverter:
|
for register in inverter:
|
||||||
body = body + f"<tr><td>{register}</td><td>{inverter.get(register)}</td></tr>"
|
body = body + f"<tr><td>{register}</td><td>{inverter.get(register)}</td></tr>"
|
||||||
export_http.html_body = body + f"</table><p>Total {len(inverter)} registers"
|
export_webserver.html_body = body + f"</table><p>Total {len(inverter)} registers"
|
||||||
|
|
||||||
body = "</p></p><table><tr><th>Configuration</th><th>Value</th>"
|
body = "</p></p><table><tr><th>Configuration</th><th>Value</th>"
|
||||||
for config in self.config_inverter:
|
for config in self.config_inverter:
|
||||||
body = body + f"<tr><td>{config}</td><td>{self.config_inverter.get(config)}</td></tr>"
|
body = body + f"<tr><td>{config}</td><td>{self.config_inverter.get(config)}</td></tr>"
|
||||||
export_http.html_body = export_http.html_body + body + f"</table></p>"
|
export_webserver.html_body = export_webserver.html_body + body + f"</table></p>"
|
||||||
logging.info("Updated Webserver Content")
|
logging.info("Webserver: Content Updated")
|
||||||
return
|
return
|
||||||
|
|
||||||
class MyServer(BaseHTTPRequestHandler):
|
class MyServer(BaseHTTPRequestHandler):
|
||||||
@@ -38,7 +38,7 @@ class MyServer(BaseHTTPRequestHandler):
|
|||||||
self.end_headers()
|
self.end_headers()
|
||||||
self.wfile.write(bytes("<html><head><title>SunGather</title><meta http-equiv='refresh' content='15'></head>", "utf-8"))
|
self.wfile.write(bytes("<html><head><title>SunGather</title><meta http-equiv='refresh' content='15'></head>", "utf-8"))
|
||||||
self.wfile.write(bytes("<body>", "utf-8"))
|
self.wfile.write(bytes("<body>", "utf-8"))
|
||||||
self.wfile.write(bytes(export_http.html_body, "utf-8"))
|
self.wfile.write(bytes(export_webserver.html_body, "utf-8"))
|
||||||
self.wfile.write(bytes("</table>", "utf-8"))
|
self.wfile.write(bytes("</table>", "utf-8"))
|
||||||
self.wfile.write(bytes("</body></html>", "utf-8"))
|
self.wfile.write(bytes("</body></html>", "utf-8"))
|
||||||
def log_message(self, format, *args):
|
def log_message(self, format, *args):
|
||||||
+37
-63
@@ -1,6 +1,7 @@
|
|||||||
registers:
|
registers:
|
||||||
- read:
|
- read:
|
||||||
- name: "serial_number"
|
- name: "serial_number"
|
||||||
|
level: 3
|
||||||
address: 4990
|
address: 4990
|
||||||
datatype: "UTF-8"
|
datatype: "UTF-8"
|
||||||
- name: "device_type_code"
|
- name: "device_type_code"
|
||||||
@@ -380,10 +381,10 @@ registers:
|
|||||||
address: 5045
|
address: 5045
|
||||||
datatype: "U16"
|
datatype: "U16"
|
||||||
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
|
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
|
||||||
- name: "Reserved"
|
# - name: "Reserved"
|
||||||
address: 5046 - 5048
|
# address: 5046 - 5048
|
||||||
datatype: "U16"
|
# datatype: "U16"
|
||||||
models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
|
# models: ["SG30KTL", "SG10KTL", "SG12KTL", "SG15KTL", "SG20KTL", "SG30KU", "SG36KTL", "SG36KU", "SG40KTL", "SG40KTL-M", "SG50KTL-M", "SG60KTL-M", "SG60KU", "SG30KTL-M", "SG30KTL-M-V31", "SG33KTL-M", "SG36KTL-M", "SG33K3J", "SG49K5J", "SG34KJ", "LP_P34KSG", "SG50KTL-M-20", "SG60KTL", "SG80KTL", "SG80KTL-20", "SG60KU-M", "SG5KTL-MT", "SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG30CX", "SG33CX", "SG36CX-US", "SG40CX", "SG50CX", "SG60CX-US", "SG110CX", "SG250HX", "SG250HX-US", "SG100CX", "SG100CX-JP", "SG250HX-IN", "SG25CX-SA", "SG75CX", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT","SG5K-D","SG8K-D"]
|
||||||
- name: "nominal_reactive_power"
|
- name: "nominal_reactive_power"
|
||||||
level: 2
|
level: 2
|
||||||
address: 5049
|
address: 5049
|
||||||
@@ -1192,66 +1193,39 @@ registers:
|
|||||||
# address: 5155-5199
|
# address: 5155-5199
|
||||||
scan: # these have to be 1 less than the first register
|
scan: # these have to be 1 less than the first register
|
||||||
- read:
|
- read:
|
||||||
- start: "5000"
|
- start: 5000
|
||||||
range: "100"
|
range: 100
|
||||||
level: 1
|
- start: 5100
|
||||||
- start: "5100"
|
range: 100
|
||||||
range: "100"
|
- start: 5200
|
||||||
level: 1
|
range: 100
|
||||||
- start: "5200"
|
- start: 6099
|
||||||
range: "100"
|
range: 100
|
||||||
level: 3
|
- start: 6199
|
||||||
- start: "6099"
|
range: 100
|
||||||
range: "100"
|
- start: 6299
|
||||||
level: 1
|
range: 100
|
||||||
hybrid: true
|
- start: 6399
|
||||||
- start: "6199"
|
range: 100
|
||||||
range: "100"
|
- start: 6499
|
||||||
level: 1
|
range: 100
|
||||||
hybrid: true
|
- start: 6599
|
||||||
- start: "6299"
|
range: 100
|
||||||
range: "100"
|
- start: 6699
|
||||||
level: 1
|
range: 100
|
||||||
hybrid: true
|
- start: 6799
|
||||||
- start: "6399"
|
range: 100
|
||||||
range: "100"
|
- start: 7012
|
||||||
level: 1
|
range: 25
|
||||||
hybrid: true
|
- start: 12999
|
||||||
- start: "6499"
|
range: 125
|
||||||
range: "100"
|
|
||||||
level: 1
|
|
||||||
hybrid: true
|
|
||||||
- start: "6599"
|
|
||||||
range: "100"
|
|
||||||
level: 1
|
|
||||||
hybrid: true
|
|
||||||
- start: "6699"
|
|
||||||
range: "100"
|
|
||||||
level: 1
|
|
||||||
hybrid: true
|
|
||||||
- start: "6799"
|
|
||||||
range: "100"
|
|
||||||
level: 1
|
|
||||||
hybrid: true
|
|
||||||
- start: "7012"
|
|
||||||
range: "25"
|
|
||||||
level: 3
|
|
||||||
- start: "12999"
|
|
||||||
range: "125"
|
|
||||||
level: 1
|
|
||||||
hybrid: true
|
|
||||||
- hold:
|
- hold:
|
||||||
# - start: "4999" # Get current date / time only
|
- start: 4999
|
||||||
# range: "7"
|
range: 10
|
||||||
- start: "4999"
|
- start: 5009
|
||||||
range: "10"
|
range: 10
|
||||||
level: 0
|
- start: 5034
|
||||||
- start: "5009"
|
range: 10
|
||||||
range: "10"
|
|
||||||
level: 2
|
|
||||||
- start: "5034"
|
|
||||||
range: "10"
|
|
||||||
level: 2
|
|
||||||
|
|
||||||
# full Models Supported:
|
# full Models Supported:
|
||||||
#["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
|
#["SG30KTL","SG10KTL","SG12KTL","SG15KTL","SG20KTL","SG30KU","SG36KTL","SG36KU","SG40KTL","SG40KTL-M","SG50KTL-M","SG60KTL-M","SG60KU","SG30KTL-M","SG30KTL-M-V31","SG33KTL-M","SG36KTL-M","SG33K3J","SG49K5J","SG34KJ","LP_P34KSG","SG50KTL-M-20","SG60KTL","SG80KTL","SG80KTL-20","SG60KU-M","SG5KTL-MT","SG6KTL-MT","SG8KTL-M","SG10KTL-M","SG10KTL-MT","SG12KTL-M","SG15KTL-M","SG17KTL-M","SG20KTL-M","SG80KTL-M","SG111HV","SG125HV","SG125HV-20","SG30CX","SG33CX","SG36CX-US","SG40CX","SG50CX","SG60CX-US","SG110CX","SG250HX","SG250HX-US","SG100CX","SG100CX-JP","SG250HX-IN","SG25CX-SA","SG75CX","SG3.0RT","SG4.0RT","SG5.0RT","SG6.0RT","SG7.0RT","SG8.0RT","SG10RT","SG12RT","SG15RT","SG17RT","SG20RT"]
|
||||||
+101
-90
@@ -17,6 +17,7 @@ import os
|
|||||||
|
|
||||||
config = None
|
config = None
|
||||||
registers = None
|
registers = None
|
||||||
|
register_ranges = None
|
||||||
inverter = None
|
inverter = None
|
||||||
client = None
|
client = None
|
||||||
|
|
||||||
@@ -54,31 +55,15 @@ def connect_inverter():
|
|||||||
def scrape_inverter():
|
def scrape_inverter():
|
||||||
global inverter
|
global inverter
|
||||||
|
|
||||||
""" Connect to the inverter and scrape the metrics """
|
scrape_start = datetime.now()
|
||||||
client.connect()
|
client.connect()
|
||||||
|
|
||||||
for scan in registers['scan']:
|
for range in register_ranges:
|
||||||
if scan.get('read'):
|
logging.debug(f'Scraping: {range.get("type")}, {range.get("start")}:{range.get("range")}')
|
||||||
for subscan in registers['scan'][0]['read']:
|
if not load_registers(range.get('type'), int(range.get('start')), int(range.get('range'))):
|
||||||
if subscan.get('level',3) <= config['inverter'].get('level',1) or config['inverter'].get('level',1) == 3:
|
return False
|
||||||
if not subscan.get('hybrid', False):
|
|
||||||
logging.debug(f'Scanning: read, {subscan.get("start")}:{subscan.get("range")}')
|
client.close()
|
||||||
if not load_registers("read", int(subscan.get('start')), int(subscan.get('range'))):
|
|
||||||
return False
|
|
||||||
elif subscan.get('hybrid', False) and config['inverter'].get('hybrid',False):
|
|
||||||
logging.debug(f'Scanning: read, {subscan.get("start")}:{subscan.get("range")}')
|
|
||||||
if not load_registers("read", int(subscan.get('start')), int(subscan.get('range'))):
|
|
||||||
return False
|
|
||||||
if scan.get('hold'):
|
|
||||||
for subscan in registers['scan'][1]['hold']:
|
|
||||||
if not subscan.get('hybrid', False):
|
|
||||||
logging.debug(f'Scanning: hold, {subscan.get("start")}:{subscan.get("range")}')
|
|
||||||
if not load_registers("hold", int(subscan.get('start')), int(subscan.get('range'))):
|
|
||||||
return False
|
|
||||||
elif subscan.get('hybrid', False) and config['inverter'].get('hybrid',False):
|
|
||||||
logging.debug(f'Scanning: hold, {subscan.get("start")}:{subscan.get("range")}')
|
|
||||||
if not load_registers("hold", int(subscan.get('start')), int(subscan.get('range'))):
|
|
||||||
return False
|
|
||||||
|
|
||||||
# Create a registers for Power imported and exported to/from Grid
|
# Create a registers for Power imported and exported to/from Grid
|
||||||
if config['inverter'].get('level',1) >= 1:
|
if config['inverter'].get('level',1) >= 1:
|
||||||
@@ -141,7 +126,9 @@ def scrape_inverter():
|
|||||||
except Exception:
|
except Exception:
|
||||||
pass
|
pass
|
||||||
|
|
||||||
client.close()
|
scrape_end = datetime.now()
|
||||||
|
logging.info(f'Inventer: Successfully scrapped in {(scrape_end - scrape_start).seconds}.{(scrape_end - scrape_start).microseconds} secs')
|
||||||
|
|
||||||
return True
|
return True
|
||||||
|
|
||||||
def load_registers(register_type, start, count=100):
|
def load_registers(register_type, start, count=100):
|
||||||
@@ -174,8 +161,8 @@ def load_registers(register_type, start, count=100):
|
|||||||
for num in range(0, count):
|
for num in range(0, count):
|
||||||
run = int(start) + num + 1
|
run = int(start) + num + 1
|
||||||
|
|
||||||
for register in registers['registers'][0]['read']:
|
for register in registers:
|
||||||
if register_type == "read" and register['address'] == run:
|
if register_type == register.get('type') and register['address'] == run:
|
||||||
register_name = register['name']
|
register_name = register['name']
|
||||||
|
|
||||||
register_value = None
|
register_value = None
|
||||||
@@ -208,66 +195,15 @@ def load_registers(register_type, start, count=100):
|
|||||||
if register.get('multiple'):
|
if register.get('multiple'):
|
||||||
register_value = round(register_value * register.get('multiple'),2)
|
register_value = round(register_value * register.get('multiple'),2)
|
||||||
|
|
||||||
# Set the final register name and value after checking model, any adjustments above included
|
# Set the final register value with adjustments above included
|
||||||
if register.get('level',3) <= config['inverter'].get('level',1) or config['inverter'].get('level',1) == 3:
|
inverter[register_name] = register_value
|
||||||
if register.get('smart_meter') and config['inverter'].get('smart_meter'):
|
break
|
||||||
inverter[register_name] = register_value
|
|
||||||
elif register.get('models') and not config['inverter'].get('level',1) == 3:
|
|
||||||
for supported_model in register.get('models'):
|
|
||||||
if supported_model == inverter.get('device_type_code'):
|
|
||||||
inverter[register_name] = register_value
|
|
||||||
else:
|
|
||||||
inverter[register_name] = register_value
|
|
||||||
|
|
||||||
for register in registers['registers'][1]['hold']:
|
|
||||||
if register_type == "hold" and register['address'] == run:
|
|
||||||
register_name = register['name']
|
|
||||||
|
|
||||||
register_value = None
|
|
||||||
# Return the 32bit value if needed
|
|
||||||
if register.get('datatype') == "U32" or register.get('datatype') == "S32":
|
|
||||||
u32_value = rr.registers[num+1]
|
|
||||||
if u32_value and register_value:
|
|
||||||
register_value = (u32_value * 65535) + register_value
|
|
||||||
|
|
||||||
# We convert a system response to a human value
|
|
||||||
if register.get('datarange'):
|
|
||||||
for value in register.get('datarange'):
|
|
||||||
if value['response'] == rr.registers[num]:
|
|
||||||
register_value = value['value']
|
|
||||||
if not register_value:
|
|
||||||
register_value = rr.registers[num]
|
|
||||||
|
|
||||||
# Adjust the value if needed
|
|
||||||
if register.get('indicator'):
|
|
||||||
indicator_value = rr.registers[num+1]
|
|
||||||
if indicator_value == 65535:
|
|
||||||
register_value = -1 * (65535 - register_value)
|
|
||||||
|
|
||||||
# If xFF (U 65535 / S 32767) then change to 0, looks better when logging / graphing
|
|
||||||
if register.get('datatype') == 'S16' and (register_value == 32767 or register_value == 65535):
|
|
||||||
register_value = 0
|
|
||||||
elif (register.get('datatype') == 'U16' or register.get('datatype') == 'S32' or register.get('datatype') == 'U32') and register_value == 65535:
|
|
||||||
register_value = 0
|
|
||||||
|
|
||||||
if register.get('multiple'):
|
|
||||||
register_value = round(register_value * register.get('multiple',0),2)
|
|
||||||
|
|
||||||
# Set the final register name and value after checking model, any adjustments above included
|
|
||||||
if register.get('level',3) <= config['inverter'].get('level',1) or config['inverter'].get('level',1) == 3:
|
|
||||||
if register.get('smart_meter') and config['inverter'].get('smart_meter'):
|
|
||||||
inverter[register_name] = register_value
|
|
||||||
elif register.get('models') and not config['inverter'].get('level',1) == 3:
|
|
||||||
for supported_model in register.get('models'):
|
|
||||||
if supported_model == inverter.get('device_type_code'):
|
|
||||||
inverter[register_name] = register_value
|
|
||||||
else:
|
|
||||||
inverter[register_name] = register_value
|
|
||||||
return True
|
return True
|
||||||
|
|
||||||
def main():
|
def main():
|
||||||
global config
|
global config
|
||||||
global registers
|
global registers
|
||||||
|
global register_ranges
|
||||||
global inverter
|
global inverter
|
||||||
global client
|
global client
|
||||||
|
|
||||||
@@ -319,7 +255,7 @@ def main():
|
|||||||
sys.exit(1)
|
sys.exit(1)
|
||||||
|
|
||||||
try:
|
try:
|
||||||
registers = yaml.safe_load(open('registers.yaml'))
|
registers_raw = yaml.safe_load(open('registers.yaml'))
|
||||||
logging.info(f"Loaded registers: {os.getcwd()}/registers.yaml")
|
logging.info(f"Loaded registers: {os.getcwd()}/registers.yaml")
|
||||||
except Exception as err:
|
except Exception as err:
|
||||||
logging.error(f"Failed: Loading registers: {os.getcwd()}/registers.yaml {err}")
|
logging.error(f"Failed: Loading registers: {os.getcwd()}/registers.yaml {err}")
|
||||||
@@ -334,18 +270,21 @@ def main():
|
|||||||
if config.get('exports'):
|
if config.get('exports'):
|
||||||
for export in config.get('exports'):
|
for export in config.get('exports'):
|
||||||
try:
|
try:
|
||||||
if export.get('enabled', True):
|
if export.get('enabled', False):
|
||||||
export_load = importlib.import_module("exports." + export.get('name'))
|
export_load = importlib.import_module("exports." + export.get('name'))
|
||||||
logging.info(f"Loaded Export: exports\{export.get('name')}")
|
logging.info(f"Loading Export: exports\{export.get('name')}")
|
||||||
exports.append(getattr(export_load, "export_" + export.get('name'))())
|
exports.append(getattr(export_load, "export_" + export.get('name'))())
|
||||||
exports[-1].configure(export, config['inverter'])
|
exports[-1].configure(export, config['inverter'])
|
||||||
logging.info(f"Configured export: {export.get('name')}")
|
|
||||||
except Exception as err:
|
except Exception as err:
|
||||||
logging.error(f"Failed loading export: {err}" +
|
logging.error(f"Failed loading export: {err}" +
|
||||||
f"\n\t\t\t Please make sure {export.get('name')}.py exists in the exports folder")
|
f"\n\t\t\t Please make sure {export.get('name')}.py exists in the exports folder")
|
||||||
|
|
||||||
client = connect_inverter()
|
client = connect_inverter()
|
||||||
inverter = {}
|
inverter = {}
|
||||||
|
registers = [[]]
|
||||||
|
registers.pop()
|
||||||
|
register_ranges = [[]]
|
||||||
|
register_ranges.pop()
|
||||||
|
|
||||||
# Inverter Model Scanning
|
# Inverter Model Scanning
|
||||||
model = 'unknown'
|
model = 'unknown'
|
||||||
@@ -353,7 +292,14 @@ def main():
|
|||||||
model = config['inverter'].get('model')
|
model = config['inverter'].get('model')
|
||||||
logging.info(f'Bypassing Model Detection, Using config: {model}')
|
logging.info(f'Bypassing Model Detection, Using config: {model}')
|
||||||
else:
|
else:
|
||||||
|
# Load just the register to detect model, then we can load the rest of registers based on returned model
|
||||||
|
for register in registers_raw['registers'][0]['read']:
|
||||||
|
if register.get('name') == "device_type_code":
|
||||||
|
register['type'] = "read"
|
||||||
|
registers.append(register)
|
||||||
|
break
|
||||||
if load_registers("read", 4999, 1):
|
if load_registers("read", 4999, 1):
|
||||||
|
registers.pop() # Remove the register, as we only needed it once
|
||||||
if isinstance(inverter.get('device_type_code'),int):
|
if isinstance(inverter.get('device_type_code'),int):
|
||||||
logging.warning(f"Unknown Type Code Detected: {inverter.get('device_type_code')}")
|
logging.warning(f"Unknown Type Code Detected: {inverter.get('device_type_code')}")
|
||||||
else:
|
else:
|
||||||
@@ -362,8 +308,66 @@ def main():
|
|||||||
else:
|
else:
|
||||||
logging.info(f'Model detection failed, please set model in config.py')
|
logging.info(f'Model detection failed, please set model in config.py')
|
||||||
|
|
||||||
|
# Load register list based om name and value after checking model
|
||||||
|
for register in registers_raw['registers'][0]['read']:
|
||||||
|
if register.get('level',3) <= config['inverter'].get('level',1) or config['inverter'].get('level',1) == 3:
|
||||||
|
register['type'] = "read"
|
||||||
|
register.pop('level')
|
||||||
|
if register.get('smart_meter') and config['inverter'].get('smart_meter'):
|
||||||
|
register.pop('models')
|
||||||
|
registers.append(register)
|
||||||
|
elif register.get('models') and not config['inverter'].get('level',1) == 3:
|
||||||
|
for supported_model in register.get('models'):
|
||||||
|
if supported_model == inverter.get('device_type_code'):
|
||||||
|
register.pop('models')
|
||||||
|
registers.append(register)
|
||||||
|
else:
|
||||||
|
registers.append(register)
|
||||||
|
|
||||||
|
for register in registers_raw['registers'][1]['hold']:
|
||||||
|
if register.get('level',3) <= config['inverter'].get('level',1) or config['inverter'].get('level',1) == 3:
|
||||||
|
register['type'] = "hold"
|
||||||
|
register.pop('level')
|
||||||
|
if register.get('smart_meter') and config['inverter'].get('smart_meter'):
|
||||||
|
register.pop('models')
|
||||||
|
registers.append(register)
|
||||||
|
elif register.get('models') and not config['inverter'].get('level',1) == 3:
|
||||||
|
for supported_model in register.get('models'):
|
||||||
|
if supported_model == inverter.get('device_type_code'):
|
||||||
|
register.pop('models')
|
||||||
|
registers.append(register)
|
||||||
|
else:
|
||||||
|
registers.append(register)
|
||||||
|
|
||||||
|
|
||||||
|
# Load register list based om name and value after checking model
|
||||||
|
for register_range in registers_raw['scan'][0]['read']:
|
||||||
|
register_range_used = False
|
||||||
|
register_range['type'] = "read"
|
||||||
|
for register in registers:
|
||||||
|
if register.get("type") == register_range.get("type"):
|
||||||
|
if register.get('address') >= register_range.get("start") and register.get('address') <= (register_range.get("start") + register_range.get("range")):
|
||||||
|
register_range_used = True
|
||||||
|
continue
|
||||||
|
if register_range_used:
|
||||||
|
register_ranges.append(register_range)
|
||||||
|
|
||||||
|
|
||||||
|
for register_range in registers_raw['scan'][1]['hold']:
|
||||||
|
register_range_used = False
|
||||||
|
register_range['type'] = "hold"
|
||||||
|
for register in registers:
|
||||||
|
if register.get("type") == register_range.get("type"):
|
||||||
|
if register.get('address') >= register_range.get("start") and register.get('address') <= (register_range.get("start") + register_range.get("range")):
|
||||||
|
register_range_used = True
|
||||||
|
continue
|
||||||
|
if register_range_used:
|
||||||
|
register_ranges.append(register_range)
|
||||||
|
|
||||||
# Core monitoring loop
|
# Core monitoring loop
|
||||||
while True:
|
while True:
|
||||||
|
|
||||||
|
loop_start = datetime.now()
|
||||||
# Clear previous inverter values, keep the model
|
# Clear previous inverter values, keep the model
|
||||||
inverter = {}
|
inverter = {}
|
||||||
inverter['device_type_code'] = model
|
inverter['device_type_code'] = model
|
||||||
@@ -373,6 +377,7 @@ def main():
|
|||||||
time.sleep(3) # Wait 3 secs for connection, resvoles issues with modbus not reconnecting on failure
|
time.sleep(3) # Wait 3 secs for connection, resvoles issues with modbus not reconnecting on failure
|
||||||
|
|
||||||
# Scrape the inverter
|
# Scrape the inverter
|
||||||
|
|
||||||
success = scrape_inverter()
|
success = scrape_inverter()
|
||||||
|
|
||||||
if(success):
|
if(success):
|
||||||
@@ -382,13 +387,19 @@ def main():
|
|||||||
else:
|
else:
|
||||||
client.close()
|
client.close()
|
||||||
client = None
|
client = None
|
||||||
logging.warning(f"Data collection failed, skipped exporting data. Retying in {config['inverter'].get('scan_interval', 30)}")
|
logging.warning(f"Data collection failed, skipped exporting data. Retying in {config['inverter'].get('scan_interval', 30)} secs")
|
||||||
|
|
||||||
if not 'runonce' in locals():
|
|
||||||
# Sleep until the next scan
|
loop_end = datetime.now()
|
||||||
time.sleep(config['inverter'].get('scan_interval', 30))
|
logging.debug(f'Processing Time: {(loop_end - loop_start).seconds}.{(loop_end - loop_start).microseconds} secs')
|
||||||
else:
|
|
||||||
|
if 'runonce' in locals():
|
||||||
sys.exit(0)
|
sys.exit(0)
|
||||||
|
|
||||||
|
# Sleep until the next scan
|
||||||
|
time.sleep(config['inverter'].get('scan_interval', 30))
|
||||||
|
|
||||||
if __name__== "__main__":
|
if __name__== "__main__":
|
||||||
main()
|
main()
|
||||||
|
|
||||||
|
sys.exit()
|
||||||
@@ -1 +1 @@
|
|||||||
__version__ = '0.1.3'
|
__version__ = '0.2.0'
|
||||||
Reference in New Issue