Station profiles

WiFiManager 3.1.0 adds an opt-in station-profile controller for applications that need a primary Wi-Fi network and one fallback. It is independent of the legacy autoConnect() flow: existing WiFiManager consumers do not need to change.

A WiFiManager application supplies its own durable store. The controller can also be used with an in-memory store for a temporary session, but credentials will not survive a restart.

Lifecycle

A profile set has exactly two fixed slots:

  • Primary (slot 0) is required whenever the controller is enabled.
  • Fallback (slot 1) is optional.
  • The last successful slot is tried first on the next connection cycle, then the remaining enabled slot.

The controller never treats the ESP SDK's saved single network as an additional source of truth. It begins one bounded connection attempt at a time, moves to the fallback after failure, and retries both profiles after a temporary loss of a previously working connection. If a new device has no valid profiles, it opens the normal configuration portal.

A candidate submitted by the portal is only committed after it connects and receives a usable IP address. A failed candidate leaves the last saved profile set intact.

Direct WiFiManager use

Implement a small store appropriate to the application. The manager neither allocates nor owns it:

class MyProfileStore final : public WiFiManagerStationProfileStore {
public:
    bool load(WiFiManagerStationProfiles& profiles) override;
    bool save(const WiFiManagerStationProfiles& profiles) override;
    bool clear() override;
};

WiFiManager wifi;
MyProfileStore profiles;

void setup() {
    wifi.setStationProfileStore(&profiles);
    wifi.setStationRecoveryInterval(30000);
    wifi.startStationConnection("Example Setup", "setup-password");
}

void loop() {
    wifi.process();
}

The store must return a complete WiFiManagerStationProfiles value. Each enabled profile has a NUL-terminated SSID of at most 32 characters and an optional NUL-terminated password of at most 64 characters. Keep slot 0 enabled; set hasPassword = false for an open network.

To stage profiles supplied by another subsystem, use startStationCandidate(candidate). It connects the primary/fallback set first and calls the store only after success. Use saveStationProfiles(profiles) only when deliberately saving without a connection check. clearStationProfiles() clears the supplied store and disconnects the station.

Portal contract

In profile mode, the existing Wi-Fi page becomes a two-profile form. It remains driven by the same JSON endpoints:

  • GET /api/wifi/meta returns profiles, activeSlot, and controller state.
  • POST /api/wifi/save accepts s0/ p0 for primary and s1/ p1 for fallback. A blank submitted password preserves an existing password; send clear0 or clear1 for an intentional open network.
  • A normal save verifies the candidate by connecting. Poll GET /api/wifi/connect-status for its result.
  • Set stationAction=save only to store the submitted profiles for a later connection attempt.

The portal requires a non-empty primary SSID. Its API never returns a password; it only reports whether one is set.

See Portal API for the shared connection-status response. The buildable Station Profiles example contains a compact EEPROM-backed store for both supported ESP targets.

Back to documentation · project overview.