Files
firmware/src/modules/Telemetry/Sensor/SEN5XSensor.cpp
T

970 lines
33 KiB
C++

#include "configuration.h"
#if !MESHTASTIC_EXCLUDE_AIR_QUALITY_SENSOR
#include "../detect/reClockI2C.h"
#include "../mesh/generated/meshtastic/telemetry.pb.h"
#include "FSCommon.h"
#include "SEN5XSensor.h"
#include "SPILock.h"
#include "SafeFile.h"
#include "TelemetrySensor.h"
#include <float.h> // FLT_MAX
#include <pb_decode.h>
#include <pb_encode.h>
SEN5XSensor::SEN5XSensor() : TelemetrySensor(meshtastic_TelemetrySensorType_SEN5X, "SEN5X") {}
bool SEN5XSensor::getVersion()
{
if (!sendCommand(SEN5X_GET_FIRMWARE_VERSION)) {
LOG_ERROR("SEN5X: Error sending version command");
return false;
}
delay(20); // From Sensirion Datasheet
uint8_t versionBuffer[12]{};
size_t charNumber = readBuffer(&versionBuffer[0], 3);
if (charNumber == 0) {
LOG_ERROR("SEN5X: Error getting data ready flag value");
return false;
}
firmwareVer = versionBuffer[0] + (versionBuffer[1] / 10);
hardwareVer = versionBuffer[3] + (versionBuffer[4] / 10);
protocolVer = versionBuffer[5] + (versionBuffer[6] / 10);
LOG_INFO("SEN5X Firmware Version: %0.2f", firmwareVer);
LOG_INFO("SEN5X Hardware Version: %0.2f", hardwareVer);
LOG_INFO("SEN5X Protocol Version: %0.2f", protocolVer);
return true;
}
bool SEN5XSensor::findModel()
{
if (!sendCommand(SEN5X_GET_PRODUCT_NAME)) {
LOG_ERROR("SEN5X: Error asking for product name");
return false;
}
delay(50); // From Sensirion Datasheet
const uint8_t nameSize = 48;
uint8_t name[nameSize];
size_t charNumber = readBuffer(&name[0], nameSize);
if (charNumber == 0) {
LOG_ERROR("SEN5X: Error getting device name");
return false;
}
// We only check the last character that defines the model SEN5X
switch (name[4]) {
case 48:
model = SEN50;
LOG_INFO("SEN5X: found sensor model SEN50");
break;
case 52:
model = SEN54;
LOG_INFO("SEN5X: found sensor model SEN54");
break;
case 53:
model = SEN55;
LOG_INFO("SEN5X: found sensor model SEN55");
break;
}
return true;
}
bool SEN5XSensor::sendCommand(uint16_t command)
{
uint8_t nothing;
return sendCommand(command, &nothing, 0);
}
bool SEN5XSensor::sendCommand(uint16_t command, uint8_t *buffer, uint8_t byteNumber)
{
// At least we need two bytes for the command
uint8_t bufferSize = 2;
// Add space for CRC bytes (one every two bytes)
if (byteNumber > 0)
bufferSize += byteNumber + (byteNumber / 2);
uint8_t toSend[bufferSize];
uint8_t i = 0;
toSend[i++] = static_cast<uint8_t>((command & 0xFF00) >> 8);
toSend[i++] = static_cast<uint8_t>((command & 0x00FF) >> 0);
// Prepare buffer with CRC every third byte
uint8_t bi = 0;
if (byteNumber > 0) {
while (bi < byteNumber) {
toSend[i++] = buffer[bi++];
toSend[i++] = buffer[bi++];
uint8_t calcCRC = sen5xCRC(&buffer[bi - 2]);
toSend[i++] = calcCRC;
}
}
#ifdef SEN5X_I2C_CLOCK_SPEED
#ifdef CAN_RECLOCK_I2C
uint32_t currentClock = reClockI2C(SEN5X_I2C_CLOCK_SPEED, _bus, false);
#elif !HAS_SCREEN
reClockI2C(SEN5X_I2C_CLOCK_SPEED, _bus, true);
#else
LOG_WARN("%s can't be used at this clock speed, with a screen", sensorName);
return false;
#endif /* CAN_RECLOCK_I2C */
#endif /* SEN5X_I2C_CLOCK_SPEED */
// Transmit the data
// LOG_DEBUG("Beginning connection to SEN5X: 0x%x. Size: %u", address, bufferSize);
// Note: this delay is necessary to allow for long-buffers
delay(20);
_bus->beginTransmission(_address);
size_t writtenBytes = _bus->write(toSend, bufferSize);
uint8_t i2c_error = _bus->endTransmission();
#if defined(SEN5X_I2C_CLOCK_SPEED) && defined(CAN_RECLOCK_I2C)
reClockI2C(currentClock, _bus, false);
#endif
if (writtenBytes != bufferSize) {
LOG_ERROR("SEN5X: Error writting on I2C bus");
return false;
}
if (i2c_error != 0) {
LOG_ERROR("SEN5X: Error on I2C communication: %x", i2c_error);
return false;
}
return true;
}
uint8_t SEN5XSensor::readBuffer(uint8_t *buffer, uint8_t byteNumber)
{
#ifdef SEN5X_I2C_CLOCK_SPEED
#ifdef CAN_RECLOCK_I2C
uint32_t currentClock = reClockI2C(SEN5X_I2C_CLOCK_SPEED, _bus, false);
#elif !HAS_SCREEN
reClockI2C(SEN5X_I2C_CLOCK_SPEED, _bus, true);
#else
LOG_WARN("%s can't be used at this clock speed, with a screen", sensorName);
return false;
#endif /* CAN_RECLOCK_I2C */
#endif /* SEN5X_I2C_CLOCK_SPEED */
size_t readBytes = _bus->requestFrom(_address, byteNumber);
if (readBytes != byteNumber) {
LOG_ERROR("SEN5X: Error reading I2C bus");
return 0;
}
uint8_t i = 0;
uint8_t receivedBytes = 0;
while (readBytes > 0) {
buffer[i++] = _bus->read(); // Just as a reminder: i++ returns i and after that increments.
buffer[i++] = _bus->read();
uint8_t recvCRC = _bus->read();
uint8_t calcCRC = sen5xCRC(&buffer[i - 2]);
if (recvCRC != calcCRC) {
LOG_ERROR("SEN5X: Checksum error while receiving msg");
return 0;
}
readBytes -= 3;
receivedBytes += 2;
}
#if defined(SEN5X_I2C_CLOCK_SPEED) && defined(CAN_RECLOCK_I2C)
reClockI2C(currentClock, _bus, false);
#endif
return receivedBytes;
}
uint8_t SEN5XSensor::sen5xCRC(const uint8_t *buffer)
{
// This code is based on Sensirion's own implementation
// https://github.com/Sensirion/arduino-core/blob/41fd02cacf307ec4945955c58ae495e56809b96c/src/SensirionCrc.cpp
uint8_t crc = 0xff;
for (uint8_t i = 0; i < 2; i++) {
crc ^= buffer[i];
for (uint8_t bit = 8; bit > 0; bit--) {
if (crc & 0x80)
crc = (crc << 1) ^ 0x31;
else
crc = (crc << 1);
}
}
return crc;
}
void SEN5XSensor::sleep()
{
idle(true);
}
bool SEN5XSensor::idle(bool checkState)
{
// From the datasheet:
// By default, the VOC algorithm resets its state to initial
// values each time a measurement is started,
// even if the measurement was stopped only for a short
// time. So, the VOC index output value needs a long time
// until it is stable again. This can be avoided by
// restoring the previously memorized algorithm state before
// starting the measure mode
if (checkState) {
// If the stabilisation period is not passed for SEN54 or SEN55, don't go to idle
if (model != SEN50) {
// Get VOC state before going to idle mode
vocValid = false;
if (vocStateFromSensor()) {
vocValid = vocStateValid();
// Check if we have time, and store it
uint32_t now; // If time is RTCQualityNone, it will return zero
now = getValidTime(RTCQuality::RTCQualityDevice);
// Check if state is valid (non-zero)
if (now) {
vocTime = now;
}
}
if (!(vocStateStable() && vocValid)) {
LOG_INFO("%s: Not stopping measurement, vocState is not stable yet!", sensorName);
return true;
}
}
// Save state and prefs (on all models)
saveState();
}
if (!oneShotMode) {
LOG_INFO("%s: Not stopping measurement, continuous mode!", sensorName);
return true;
} else {
LOG_INFO("%s: One shot mode enabled", sensorName);
}
// Switch to low-power based on the model
if (model == SEN50) {
if (!sendCommand(SEN5X_STOP_MEASUREMENT)) {
LOG_ERROR("%s: Error stopping measurement", sensorName);
return false;
}
state = SEN5X_IDLE;
LOG_INFO("%s: Stop measurement mode", sensorName);
} else {
if (!sendCommand(SEN5X_START_MEASUREMENT_RHT_GAS)) {
LOG_ERROR("%s: Error switching to RHT/Gas measurement", sensorName);
return false;
}
state = SEN5X_RHTGAS_ONLY;
LOG_INFO("%s: Switch to RHT/Gas only measurement mode", sensorName);
}
delay(200); // From Sensirion Datasheet
pmMeasureStarted = 0;
return true;
}
bool SEN5XSensor::vocStateRecent(uint32_t now)
{
if (now) {
uint32_t passed = now - vocTime; // in seconds
// Check if state is recent, less than 10 minutes (600 seconds)
if (passed < SEN5X_VOC_VALID_TIME && (now > SEN5X_VOC_VALID_DATE)) {
return true;
}
}
return false;
}
bool SEN5XSensor::vocStateValid()
{
if (!vocState[0] && !vocState[1] && !vocState[2] && !vocState[3] && !vocState[4] && !vocState[5] && !vocState[6] &&
!vocState[7]) {
LOG_DEBUG("%s: VOC state is all 0, invalid", sensorName);
return false;
} else {
LOG_DEBUG("%s: VOC state is valid", sensorName);
return true;
}
}
bool SEN5XSensor::vocStateToSensor()
{
if (model == SEN50) {
return true;
}
if (!vocStateValid()) {
LOG_INFO("SEN5X: VOC state is invalid, not sending");
return true;
}
if (!sendCommand(SEN5X_STOP_MEASUREMENT)) {
LOG_ERROR("SEN5X: Error stoping measurement");
return false;
}
delay(200); // From Sensirion Datasheet
LOG_DEBUG("SEN5X: Sending VOC state to sensor");
LOG_DEBUG("[%u, %u, %u, %u, %u, %u, %u, %u]", vocState[0], vocState[1], vocState[2], vocState[3], vocState[4], vocState[5],
vocState[6], vocState[7]);
// Note: send command already takes into account the CRC
// buffer size increment needed
if (!sendCommand(SEN5X_RW_VOCS_STATE, vocState, SEN5X_VOC_STATE_BUFFER_SIZE)) {
LOG_ERROR("SEN5X: Error sending VOC's state command'");
return false;
}
return true;
}
bool SEN5XSensor::vocStateFromSensor()
{
if (model == SEN50) {
return true;
}
LOG_INFO("SEN5X: Getting VOC state from sensor");
// Ask VOCs state from the sensor
if (!sendCommand(SEN5X_RW_VOCS_STATE)) {
LOG_ERROR("SEN5X: Error sending VOC's state command'");
return false;
}
delay(20); // From Sensirion Datasheet
// Retrieve the data
// Allocate buffer to account for CRC
size_t receivedNumber = readBuffer(&vocState[0], SEN5X_VOC_STATE_BUFFER_SIZE + (SEN5X_VOC_STATE_BUFFER_SIZE / 2));
delay(20); // From Sensirion Datasheet
if (receivedNumber == 0) {
LOG_DEBUG("SEN5X: Error getting VOC's state");
return false;
}
// Print the state (if debug is on)
LOG_DEBUG("SEN5X: VOC state retrieved from sensor: [%u, %u, %u, %u, %u, %u, %u, %u]", vocState[0], vocState[1], vocState[2],
vocState[3], vocState[4], vocState[5], vocState[6], vocState[7]);
return true;
}
bool SEN5XSensor::loadState()
{
#ifdef FSCom
spiLock->lock();
auto file = FSCom.open(sen5XStateFileName, FILE_O_READ);
bool okay = false;
if (file) {
LOG_INFO("%s state read from %s", sensorName, sen5XStateFileName);
pb_istream_t stream = {&readcb, &file, meshtastic_SEN5XState_size};
if (!pb_decode(&stream, &meshtastic_SEN5XState_msg, &sen5xstate)) {
LOG_ERROR("Error: can't decode protobuf %s", PB_GET_ERROR(&stream));
} else {
lastCleaning = sen5xstate.last_cleaning_time;
lastCleaningValid = sen5xstate.last_cleaning_valid;
oneShotMode = sen5xstate.one_shot_mode;
if (model != SEN50) {
vocTime = sen5xstate.voc_state_time;
vocValid = sen5xstate.voc_state_valid;
// Unpack state
vocState[7] = (uint8_t)(sen5xstate.voc_state_array >> 56);
vocState[6] = (uint8_t)(sen5xstate.voc_state_array >> 48);
vocState[5] = (uint8_t)(sen5xstate.voc_state_array >> 40);
vocState[4] = (uint8_t)(sen5xstate.voc_state_array >> 32);
vocState[3] = (uint8_t)(sen5xstate.voc_state_array >> 24);
vocState[2] = (uint8_t)(sen5xstate.voc_state_array >> 16);
vocState[1] = (uint8_t)(sen5xstate.voc_state_array >> 8);
vocState[0] = (uint8_t)sen5xstate.voc_state_array;
}
// LOG_DEBUG("Loaded lastCleaning %u", lastCleaning);
// LOG_DEBUG("Loaded lastCleaningValid %u", lastCleaningValid);
// LOG_DEBUG("Loaded oneShotMode %s", oneShotMode ? "true" : "false");
// LOG_DEBUG("Loaded vocTime %u", vocTime);
// LOG_DEBUG("Loaded [%u, %u, %u, %u, %u, %u, %u, %u]",
// vocState[7], vocState[6], vocState[5], vocState[4], vocState[3], vocState[2], vocState[1], vocState[0]);
// LOG_DEBUG("Loaded %svalid VOC state", vocValid ? "" : "in");
okay = true;
}
file.close();
} else {
LOG_INFO("No %s state found (File: %s)", sensorName, sen5XStateFileName);
}
spiLock->unlock();
return okay;
#else
LOG_ERROR("SEN5X: ERROR - Filesystem not implemented");
#endif
}
bool SEN5XSensor::saveState()
{
#ifdef FSCom
auto file = SafeFile(sen5XStateFileName);
sen5xstate.last_cleaning_time = lastCleaning;
sen5xstate.last_cleaning_valid = lastCleaningValid;
sen5xstate.one_shot_mode = oneShotMode;
if (model != SEN50) {
sen5xstate.has_voc_state_time = true;
sen5xstate.has_voc_state_valid = true;
sen5xstate.has_voc_state_array = true;
sen5xstate.voc_state_time = vocTime;
sen5xstate.voc_state_valid = vocValid;
// Unpack state (8 bytes)
sen5xstate.voc_state_array = (((uint64_t)vocState[7]) << 56) | ((uint64_t)vocState[6] << 48) |
((uint64_t)vocState[5] << 40) | ((uint64_t)vocState[4] << 32) |
((uint64_t)vocState[3] << 24) | ((uint64_t)vocState[2] << 16) |
((uint64_t)vocState[1] << 8) | ((uint64_t)vocState[0]);
}
bool okay = false;
LOG_INFO("%s: state write to %s", sensorName, sen5XStateFileName);
pb_ostream_t stream = {&writecb, static_cast<Print *>(&file), meshtastic_SEN5XState_size};
if (!pb_encode(&stream, &meshtastic_SEN5XState_msg, &sen5xstate)) {
LOG_ERROR("Error: can't encode protobuf %s", PB_GET_ERROR(&stream));
} else {
okay = true;
}
okay &= file.close();
if (okay)
LOG_INFO("%s: state write to %s successful", sensorName, sen5XStateFileName);
return okay;
#else
LOG_ERROR("%s: ERROR - Filesystem not implemented", sensorName);
#endif
}
bool SEN5XSensor::isActive()
{
return state == SEN5X_MEASUREMENT || state == SEN5X_MEASUREMENT_2;
}
uint32_t SEN5XSensor::wakeUp()
{
LOG_DEBUG("SEN5X: Waking up sensor");
if (!sendCommand(SEN5X_START_MEASUREMENT)) {
LOG_ERROR("SEN5X: Error starting measurement");
// TODO - what should this return?? Something actually on the default interval?
return DEFAULT_SENSOR_MINIMUM_WAIT_TIME_BETWEEN_READS;
}
delay(50); // From Sensirion Datasheet
// TODO - This is currently "problematic"
// If time is updated in between reads, there is no way to
// keep track of how long it has passed
pmMeasureStarted = getTime();
state = SEN5X_MEASUREMENT;
if (state == SEN5X_MEASUREMENT)
LOG_INFO("SEN5X: Started measurement mode");
return SEN5X_WARMUP_MS_1;
}
bool SEN5XSensor::vocStateStable()
{
uint32_t now;
now = getTime();
uint32_t sinceFirstMeasureStarted = (now - rhtGasMeasureStarted);
LOG_DEBUG("sinceFirstMeasureStarted: %us", sinceFirstMeasureStarted);
return sinceFirstMeasureStarted > SEN5X_VOC_STATE_WARMUP_S;
}
bool SEN5XSensor::startCleaning()
{
// Note: we only should enter here if we have a valid RTC with at least
// RTCQuality::RTCQualityDevice
state = SEN5X_CLEANING;
// Note that cleaning command can only be run when the sensor is in measurement mode
if (!sendCommand(SEN5X_START_MEASUREMENT)) {
LOG_ERROR("SEN5X: Error starting measurment mode");
return false;
}
delay(50); // From Sensirion Datasheet
if (!sendCommand(SEN5X_START_FAN_CLEANING)) {
LOG_ERROR("SEN5X: Error starting fan cleaning");
return false;
}
delay(20); // From Sensirion Datasheet
// This message will be always printed so the user knows the device it's not hung
LOG_INFO("SEN5X: Started fan cleaning it will take 10 seconds...");
uint16_t started = millis();
while (millis() - started < 10500) {
delay(500);
}
LOG_INFO("SEN5X: Cleaning done!!");
// Save timestamp in flash so we know when a week has passed
uint32_t now;
now = getValidTime(RTCQuality::RTCQualityDevice);
// If time is not RTCQualityNone, it will return non-zero
lastCleaning = now;
lastCleaningValid = true;
saveState();
idle();
return true;
}
bool SEN5XSensor::initDevice(TwoWire *bus, ScanI2C::FoundDevice *dev)
{
state = SEN5X_NOT_DETECTED;
LOG_INFO("Init sensor: %s", sensorName);
_bus = bus;
_address = dev->address.address;
delay(50); // without this there is an error on the deviceReset function
if (!sendCommand(SEN5X_RESET)) {
LOG_ERROR("SEN5X: Error reseting device");
return false;
}
delay(200); // From Sensirion Datasheet
if (!findModel()) {
LOG_ERROR("SEN5X: error finding sensor model");
return false;
}
// Check the firmware version
if (!getVersion())
return false;
if (firmwareVer < 2) {
LOG_ERROR("SEN5X: error firmware is too old and will not work with this implementation");
return false;
}
delay(200); // From Sensirion Datasheet
// Detection succeeded
state = SEN5X_IDLE;
status = 1;
// Load state
loadState();
// Check if it is time to do a cleaning
uint32_t now;
int32_t passed = 0;
now = getValidTime(RTCQuality::RTCQualityDevice);
// If time is not RTCQualityNone, it will return non-zero
if (now) {
if (lastCleaningValid) {
passed = now - lastCleaning; // in seconds
if (passed > ONE_WEEK_IN_SECONDS && (now > SEN5X_VOC_VALID_DATE)) {
// If current date greater than 01/01/2018 (validity check)
LOG_INFO("SEN5X: More than a week (%us) since last cleaning in epoch (%us). Trigger, cleaning...", passed,
lastCleaning);
startCleaning();
} else {
LOG_INFO("SEN5X: Cleaning not needed (%ds passed). Last cleaning date (in epoch): %us", passed, lastCleaning);
}
} else {
// We assume the device has just been updated or it is new,
// so no need to trigger a cleaning.
// Just save the timestamp to do a cleaning one week from now.
// Otherwise, we will never trigger cleaning in some cases
lastCleaning = now;
lastCleaningValid = true;
LOG_INFO("SEN5X: No valid last cleaning date found, saving it now: %us", lastCleaning);
saveState();
}
if (model != SEN50) {
if (!vocValid) {
LOG_INFO("SEN5X: No valid VOC's state found");
} else {
// Check if state is recent
if (vocStateRecent(now)) {
// If current date greater than 01/01/2018 (validity check)
// Send it to the sensor
LOG_INFO("SEN5X: VOC state is valid and recent");
vocStateToSensor();
} else {
LOG_INFO("SEN5X: VOC state is too old or date is invalid");
LOG_DEBUG("SEN5X: vocTime %u, Passed %u, and now %u", vocTime, passed, now);
}
}
}
} else {
// TODO - Should this actually ignore? We could end up never cleaning...
LOG_INFO("SEN5X: Not enough RTCQuality, ignoring saved cleaning and VOC state");
}
idle(false);
rhtGasMeasureStarted = now;
initI2CSensor();
return true;
}
bool SEN5XSensor::readValues()
{
if (!sendCommand(SEN5X_READ_VALUES)) {
LOG_ERROR("SEN5X: Error sending read command");
return false;
}
LOG_DEBUG("SEN5X: Reading PM Values");
delay(20); // From Sensirion Datasheet
uint8_t dataBuffer[16]{};
size_t receivedNumber = readBuffer(&dataBuffer[0], 24);
if (receivedNumber == 0) {
LOG_ERROR("SEN5X: Error getting values");
return false;
}
// Get the integers
uint16_t uint_pM1p0 = static_cast<uint16_t>((dataBuffer[0] << 8) | dataBuffer[1]);
uint16_t uint_pM2p5 = static_cast<uint16_t>((dataBuffer[2] << 8) | dataBuffer[3]);
uint16_t uint_pM4p0 = static_cast<uint16_t>((dataBuffer[4] << 8) | dataBuffer[5]);
uint16_t uint_pM10p0 = static_cast<uint16_t>((dataBuffer[6] << 8) | dataBuffer[7]);
int16_t int_humidity = static_cast<int16_t>((dataBuffer[8] << 8) | dataBuffer[9]);
int16_t int_temperature = static_cast<int16_t>((dataBuffer[10] << 8) | dataBuffer[11]);
int16_t int_vocIndex = static_cast<int16_t>((dataBuffer[12] << 8) | dataBuffer[13]);
int16_t int_noxIndex = static_cast<int16_t>((dataBuffer[14] << 8) | dataBuffer[15]);
// Convert values based on Sensirion Arduino lib
sen5xmeasurement.pM1p0 = !isnan(uint_pM1p0) ? uint_pM1p0 / 10 : UINT16_MAX;
sen5xmeasurement.pM2p5 = !isnan(uint_pM2p5) ? uint_pM2p5 / 10 : UINT16_MAX;
sen5xmeasurement.pM4p0 = !isnan(uint_pM4p0) ? uint_pM4p0 / 10 : UINT16_MAX;
sen5xmeasurement.pM10p0 = !isnan(uint_pM10p0) ? uint_pM10p0 / 10 : UINT16_MAX;
sen5xmeasurement.humidity = !isnan(int_humidity) ? int_humidity / 100.0f : FLT_MAX;
sen5xmeasurement.temperature = !isnan(int_temperature) ? int_temperature / 200.0f : FLT_MAX;
sen5xmeasurement.vocIndex = !isnan(int_vocIndex) ? int_vocIndex / 10.0f : FLT_MAX;
sen5xmeasurement.noxIndex = !isnan(int_noxIndex) ? int_noxIndex / 10.0f : FLT_MAX;
LOG_DEBUG("Got %s readings: pM1p0=%u, pM2p5=%u, pM4p0=%u, pM10p0=%u", sensorName, sen5xmeasurement.pM1p0,
sen5xmeasurement.pM2p5, sen5xmeasurement.pM4p0, sen5xmeasurement.pM10p0);
if (model != SEN50) {
LOG_DEBUG("Got %s readings: humidity=%.2f, temperature=%.2f, vocIndex=%.2f", sensorName, sen5xmeasurement.humidity,
sen5xmeasurement.temperature, sen5xmeasurement.vocIndex);
}
if (model == SEN55) {
LOG_DEBUG("Got %s readings: noxIndex=%.2f", sensorName, sen5xmeasurement.noxIndex);
}
return true;
}
bool SEN5XSensor::readPNValues(bool cumulative)
{
if (!sendCommand(SEN5X_READ_PM_VALUES)) {
LOG_ERROR("SEN5X: Error sending read command");
return false;
}
LOG_DEBUG("SEN5X: Reading PN Values");
delay(20); // From Sensirion Datasheet
uint8_t dataBuffer[20]{};
size_t receivedNumber = readBuffer(&dataBuffer[0], 30);
if (receivedNumber == 0) {
LOG_ERROR("SEN5X: Error getting PN values");
return false;
}
// Get the integers
// uint16_t uint_pM1p0 = static_cast<uint16_t>((dataBuffer[0] << 8) | dataBuffer[1]);
// uint16_t uint_pM2p5 = static_cast<uint16_t>((dataBuffer[2] << 8) | dataBuffer[3]);
// uint16_t uint_pM4p0 = static_cast<uint16_t>((dataBuffer[4] << 8) | dataBuffer[5]);
// uint16_t uint_pM10p0 = static_cast<uint16_t>((dataBuffer[6] << 8) | dataBuffer[7]);
uint16_t uint_pN0p5 = static_cast<uint16_t>((dataBuffer[8] << 8) | dataBuffer[9]);
uint16_t uint_pN1p0 = static_cast<uint16_t>((dataBuffer[10] << 8) | dataBuffer[11]);
uint16_t uint_pN2p5 = static_cast<uint16_t>((dataBuffer[12] << 8) | dataBuffer[13]);
uint16_t uint_pN4p0 = static_cast<uint16_t>((dataBuffer[14] << 8) | dataBuffer[15]);
uint16_t uint_pN10p0 = static_cast<uint16_t>((dataBuffer[16] << 8) | dataBuffer[17]);
uint16_t uint_tSize = static_cast<uint16_t>((dataBuffer[18] << 8) | dataBuffer[19]);
// Convert values based on Sensirion Arduino lib
// Multiply by 100 for converting from #/cm3 to #/0.1l for PN values
sen5xmeasurement.pN0p5 = !isnan(uint_pN0p5) ? uint_pN0p5 / 10 * 100 : UINT32_MAX;
sen5xmeasurement.pN1p0 = !isnan(uint_pN1p0) ? uint_pN1p0 / 10 * 100 : UINT32_MAX;
sen5xmeasurement.pN2p5 = !isnan(uint_pN2p5) ? uint_pN2p5 / 10 * 100 : UINT32_MAX;
sen5xmeasurement.pN4p0 = !isnan(uint_pN4p0) ? uint_pN4p0 / 10 * 100 : UINT32_MAX;
sen5xmeasurement.pN10p0 = !isnan(uint_pN10p0) ? uint_pN10p0 / 10 * 100 : UINT32_MAX;
sen5xmeasurement.tSize = !isnan(uint_tSize) ? uint_tSize / 1000.0f : FLT_MAX;
// Remove accumuluative values:
// https://github.com/fablabbcn/smartcitizen-kit-2x/issues/85
if (!cumulative) {
sen5xmeasurement.pN10p0 -= sen5xmeasurement.pN4p0;
sen5xmeasurement.pN4p0 -= sen5xmeasurement.pN2p5;
sen5xmeasurement.pN2p5 -= sen5xmeasurement.pN1p0;
sen5xmeasurement.pN1p0 -= sen5xmeasurement.pN0p5;
}
LOG_DEBUG("Got %s readings: pN0p5=%u, pN1p0=%u, pN2p5=%u, pN4p0=%u, pN10p0=%u, tSize=%.2f", sensorName,
sen5xmeasurement.pN0p5, sen5xmeasurement.pN1p0, sen5xmeasurement.pN2p5, sen5xmeasurement.pN4p0,
sen5xmeasurement.pN10p0, sen5xmeasurement.tSize);
return true;
}
uint8_t SEN5XSensor::getMeasurements()
{
uint32_t now;
now = getTime();
// Try to get new data
if (!sendCommand(SEN5X_READ_DATA_READY)) {
LOG_ERROR("SEN5X: Error sending command data ready flag");
return 2;
}
delay(20); // From Sensirion Datasheet
uint8_t dataReadyBuffer[3];
size_t charNumber = readBuffer(&dataReadyBuffer[0], 3);
if (charNumber == 0) {
LOG_ERROR("SEN5X: Error getting device version value");
return 2;
}
bool dataReady = dataReadyBuffer[1];
uint32_t sinceLastDataPollMs = (now - lastDataPoll) * 1000;
// Check if data is ready, and if since last time we requested is less than SEN5X_POLL_INTERVAL
if (!dataReady && (sinceLastDataPollMs > SEN5X_POLL_INTERVAL)) {
LOG_INFO("SEN5X: Data is not ready");
return 1;
}
if (!readValues()) {
LOG_ERROR("SEN5X: Error getting readings");
return 2;
}
if (!readPNValues(false)) {
LOG_ERROR("SEN5X: Error getting PN readings");
return 2;
}
lastDataPoll = now;
return 0;
}
int32_t SEN5XSensor::wakeUpTimeMs()
{
return SEN5X_WARMUP_MS_2;
}
int32_t SEN5XSensor::pendingForReadyMs()
{
uint32_t now;
now = getTime();
uint32_t sincePmMeasureStarted = (now - pmMeasureStarted) * 1000;
LOG_DEBUG("SEN5X: Since measure started: %ums", sincePmMeasureStarted);
switch (state) {
case SEN5X_MEASUREMENT: {
if (sincePmMeasureStarted < SEN5X_WARMUP_MS_1) {
LOG_INFO("SEN5X: not enough time passed since starting measurement");
return SEN5X_WARMUP_MS_1 - sincePmMeasureStarted;
}
if (!pmMeasureStarted) {
pmMeasureStarted = now;
}
// Get PN values to check if we are above or below threshold
readPNValues(true);
lastDataPoll = now;
// If the reading is low (the tyhreshold is in #/cm3) and second warmUp hasn't passed we return to come back later
if ((sen5xmeasurement.pN4p0 / 100) < SEN5X_PN4P0_CONC_THD && sincePmMeasureStarted < SEN5X_WARMUP_MS_2) {
LOG_INFO("SEN5X: Concentration is low, we will ask again in the second warm up period");
state = SEN5X_MEASUREMENT_2;
// Report how many seconds are pending to cover the first warm up period
return SEN5X_WARMUP_MS_2 - sincePmMeasureStarted;
}
return 0;
}
case SEN5X_MEASUREMENT_2: {
if (sincePmMeasureStarted < SEN5X_WARMUP_MS_2) {
// Report how many seconds are pending to cover the first warm up period
return SEN5X_WARMUP_MS_2 - sincePmMeasureStarted;
}
return 0;
}
default: {
return -1;
}
}
}
bool SEN5XSensor::getMetrics(meshtastic_Telemetry *measurement)
{
LOG_INFO("SEN5X: Attempting to get metrics");
if (!isActive()) {
LOG_INFO("SEN5X: not in measurement mode");
return false;
}
uint8_t response;
response = getMeasurements();
if (response == 0) {
if (sen5xmeasurement.pM1p0 != UINT16_MAX) {
measurement->variant.air_quality_metrics.has_pm10_standard = true;
measurement->variant.air_quality_metrics.pm10_standard = sen5xmeasurement.pM1p0;
}
if (sen5xmeasurement.pM2p5 != UINT16_MAX) {
measurement->variant.air_quality_metrics.has_pm25_standard = true;
measurement->variant.air_quality_metrics.pm25_standard = sen5xmeasurement.pM2p5;
}
if (sen5xmeasurement.pM4p0 != UINT16_MAX) {
measurement->variant.air_quality_metrics.has_pm40_standard = true;
measurement->variant.air_quality_metrics.pm40_standard = sen5xmeasurement.pM4p0;
}
if (sen5xmeasurement.pM10p0 != UINT16_MAX) {
measurement->variant.air_quality_metrics.has_pm100_standard = true;
measurement->variant.air_quality_metrics.pm100_standard = sen5xmeasurement.pM10p0;
}
if (sen5xmeasurement.pN0p5 != UINT32_MAX) {
measurement->variant.air_quality_metrics.has_particles_05um = true;
measurement->variant.air_quality_metrics.particles_05um = sen5xmeasurement.pN0p5;
}
if (sen5xmeasurement.pN1p0 != UINT32_MAX) {
measurement->variant.air_quality_metrics.has_particles_10um = true;
measurement->variant.air_quality_metrics.particles_10um = sen5xmeasurement.pN1p0;
}
if (sen5xmeasurement.pN2p5 != UINT32_MAX) {
measurement->variant.air_quality_metrics.has_particles_25um = true;
measurement->variant.air_quality_metrics.particles_25um = sen5xmeasurement.pN2p5;
}
if (sen5xmeasurement.pN4p0 != UINT32_MAX) {
measurement->variant.air_quality_metrics.has_particles_40um = true;
measurement->variant.air_quality_metrics.particles_40um = sen5xmeasurement.pN4p0;
}
if (sen5xmeasurement.pN10p0 != UINT32_MAX) {
measurement->variant.air_quality_metrics.has_particles_100um = true;
measurement->variant.air_quality_metrics.particles_100um = sen5xmeasurement.pN10p0;
}
if (sen5xmeasurement.tSize != FLT_MAX) {
measurement->variant.air_quality_metrics.has_particles_tps = true;
measurement->variant.air_quality_metrics.particles_tps = sen5xmeasurement.tSize;
}
if (model != SEN50) {
if (sen5xmeasurement.humidity != FLT_MAX) {
measurement->variant.air_quality_metrics.has_pm_humidity = true;
measurement->variant.air_quality_metrics.pm_humidity = sen5xmeasurement.humidity;
}
if (sen5xmeasurement.temperature != FLT_MAX) {
measurement->variant.air_quality_metrics.has_pm_temperature = true;
measurement->variant.air_quality_metrics.pm_temperature = sen5xmeasurement.temperature;
}
if (sen5xmeasurement.noxIndex != FLT_MAX) {
measurement->variant.air_quality_metrics.has_pm_voc_idx = true;
measurement->variant.air_quality_metrics.pm_voc_idx = sen5xmeasurement.vocIndex;
}
}
if (model == SEN55) {
if (sen5xmeasurement.noxIndex != FLT_MAX) {
measurement->variant.air_quality_metrics.has_pm_nox_idx = true;
measurement->variant.air_quality_metrics.pm_nox_idx = sen5xmeasurement.noxIndex;
}
}
return true;
} else if (response == 1) {
// TODO return because data was not ready yet
// Should this return false?
idle();
return false;
} else if (response == 2) {
// Return with error for non-existing data
idle();
return false;
}
return true;
}
void SEN5XSensor::setMode(bool setOneShot)
{
oneShotMode = setOneShot;
if (oneShotMode) {
LOG_INFO("%s setting mode to one shot mode", sensorName);
} else {
LOG_INFO("%s setting mode to continuous mode", sensorName);
}
}
AdminMessageHandleResult SEN5XSensor::handleAdminMessage(const meshtastic_MeshPacket &mp, meshtastic_AdminMessage *request,
meshtastic_AdminMessage *response)
{
AdminMessageHandleResult result;
result = AdminMessageHandleResult::NOT_HANDLED;
switch (request->which_payload_variant) {
case meshtastic_AdminMessage_sensor_config_tag:
if (!request->sensor_config.has_sen5x_config) {
result = AdminMessageHandleResult::NOT_HANDLED;
break;
}
// Check for one-shot/continuous mode request
if (request->sensor_config.sen5x_config.has_set_one_shot_mode) {
this->setMode(request->sensor_config.sen5x_config.set_one_shot_mode);
}
// TODO - Add admin command to set temperature offset?
// Check for temperature offset
// if (request->sensor_config.sen5x_config.has_set_temperature) {
// this->setTemperature(request->sensor_config.sen5x_config.set_temperature);
// }
// TODO - Add admin command to trigger fan cleaning?
// Check for one-shot/continuous mode request
// if (request->sensor_config.sen5x_config.has_fan_cleaning && request->sensor_config.sen5x_config.fan_cleaning) {
// this->startCleaning();
// }
result = AdminMessageHandleResult::HANDLED;
break;
default:
result = AdminMessageHandleResult::NOT_HANDLED;
}
return result;
}
#endif