add notes where smar_meter is mentioned
* smart_meter = true is not needed for hybrid models even a smart_meter is installed (smartmeter is always installed with hybrid ones) * add some notes to usefull registers for hybrid models
This commit is contained in:
@@ -149,7 +149,7 @@ Set the following in config.yaml under inverters section.
|
||||
* Level: 2 - This should be everything your inverter supports
|
||||
* Level: 3 - This will try every register, you will get lots of 0/65535 responses for registers not supported.
|
||||
|
||||
* smart_meter: True - Set to true if you have a smart reader installed, this will return power usage at the meter box, without it you can not calculate house power usage.
|
||||
* smart_meter: True - (_Only needed for SG* Models_) Set to true if you have a smart meter installed, this will return power usage at the meter box, without it you can not calculate house power usage. Hybrid inverters will provide this by default (load_power_hybrid)
|
||||
|
||||
### Useful Registers:
|
||||
This is just a brief list of registers I have found useful
|
||||
@@ -159,19 +159,23 @@ This is just a brief list of registers I have found useful
|
||||
**total_running_time** - Total Hours inverter has been powered on since install
|
||||
**internal_temperature** - Internal temperature of the Inverter
|
||||
**total_active_power** - Current power being generated by the inverter in Watts
|
||||
**meter_power** - Power usage at the meter box, needs a smart meter installed. +ve means consuming from the grid, -ve means exporting to the grid
|
||||
**meter_power** - (_SG* Models_)Power usage at the meter box, needs a smart meter installed. +ve means consuming from the grid, -ve means exporting to the grid
|
||||
**load_power** - Power being consumed in total
|
||||
**export_to_grid** - How much being currently exported to the grid. This is calculated from meter_power if -ve value, returned as a positive value
|
||||
**import_from_grid** - How much being currently imported from grid. This is calculated from meter_power if +ve value
|
||||
**load_power_hybrid** - (_SH* Models only_) Power being consumed in total
|
||||
**export_to_grid** - How much being currently exported to the grid.
|
||||
For SG* Models this is calculated from meter_power if -ve value, returned as a positive value. (_For Hybrid models export_power_hybrid is used_)
|
||||
**import_from_grid** - How much being currently imported from grid. This is calculated from meter_power if +ve value (_for hybrid models export_power_hybrid [will be negative when importing from grid] is used)
|
||||
**timestamp** - Last time data was collected, based on Inverters clock by default
|
||||
|
||||
<p align="right">(<a href="#top">back to top</a>)</p>
|
||||
|
||||
## Home Assistant setup
|
||||
|
||||
In the SunGather config.yaml you need to set the smart_meter if you have one;
|
||||
In the SunGather config.yaml you need to set the smart_meter if you have one
|
||||
_For Hybrid Models smart_meter doesn't need to get enabled_
|
||||
|
||||
```
|
||||
# Only for SG* Models
|
||||
smart_meter: True
|
||||
```
|
||||
|
||||
@@ -221,6 +225,8 @@ Solar Panels > Solar Production -> Solar Production (Sungather)
|
||||
## Tested
|
||||
* SG7.0RT with WiNet-S Dongle
|
||||
* SG10RT with WiNet-S Dongle and Ethernet (Credit: @rark-ha)
|
||||
* SH6.0RT with WiNet-S Dongle
|
||||