inverter:
host: 192.168.1.100
# port: 502 # Default for modbus is 502, for http is 8082
# slave: 0x01 # Default is 0x01
# timeout: 10 # Default is 10
# scan_interval: 30 # Default is 30
connection: sungrow # options: modbus, sungrow, http
# model: "SG7.0RT" # This is autodetected on startup, only needed if detection issues or for testing
host: 192.168.1.100 # [Required] IP Address of the Inverter or Dongle
# port: 502 # [Optional] Default for modbus is 502, for http is 8082
# slave: 0x01 # [Optional] Default is 0x01
# timeout: 10 # [Optional] Default is 10
# scan_interval: 30 # [Optional] Default is 30
connection: sungrow # [Required] options: modbus, sungrow, http
# model: "SG7.0RT" # [Optional] This is autodetected on startup, only needed if detection issues or for testing
# See model list here: https://github.com/bohdan-s/SunGather#supported
# smart_meter: True # Default is False, Set to true if inverter supports reading grind / house consumption
# use_local_time: False # Default False, Uses Inventer time, if try uses PC time when updating timestamps (e.g. PVOutput)
# hybrid: False # Default false, if you have a Hybrid (battery) set to True
# manual_load: False # Manually calculate load total_active_power + meter_power if the inverter does not supply it
# logging: 30 # 10 = Debug, 20 = Info, 30 = Warning (default), 40 = Error
# level: 1 # 0 = Model and Solar Generation,
# smart_meter: True # [Optional] Default is False, Set to true if inverter supports reading grind / house consumption
# use_local_time: False # [Optional] Default False, Uses Inventer time, if try uses PC time when updating timestamps (e.g. PVOutput)
# hybrid: False # [Optional] Default false, if you have a Hybrid (battery) set to True
# manual_load: False # [Optional] Manually calculate load total_active_power + meter_power if the inverter does not supply it
# logging: 30 # [Optional] 10 = Debug, 20 = Info, 30 = Warning (default), 40 = Error
# level: 1 # [Optional] Set the amount of information to gather
# 0 = Model and Solar Generation,
# 1 (default) = Useful data, all required for exports,
# 2 everything your Inverter supports,
# 3 Everything from every register
exports:
- name: console # Print Registers to console, good for debugging / troubleshooting
# Print Registers to console, good for debugging / troubleshooting
- name: console
enabled: False
- name: http
# Runs a simple Webserver showing Config and last read registers
- name: http
enabled: True # Access at http://localhost:8080 or http://[serverip]:8080
# port: 8080 # Default port is 8080
- name: mqtt # Publish Registers to MQTT / Home Assistant
# Output data to InfluxDB
- name: influxdb
enabled: False
token: "xxx" # [Required] API Token
url: "http://localhost:8086" # [Optional] Default URL is http://localhost:8086
org: "influxdata@bohdan.net" # [Required] InfluxDB Organization
bucket: "SunGather" # [Required] InfluxDB Bucket
measurements:
- point: "power"
register: daily_power_yields
- point: "power"
register: total_active_power
- point: "power"
register: load_power
- point: "power"
register: meter_power
- point: "power"
register: export_to_grid
- point: "power"
register: import_from_grid
- point: "temp"
register: internal_temperature
# Publish Registers to MQTT / Home Assistant
- name: mqtt
host: 192.168.1.200
# port: 1883
topic: "tele/inverter_{model}/SENSOR" # Variable {model} will be replaced with model number