mirror of
https://github.com/alexhopeoconnor/SunGather.git
synced 2026-10-04 02:48:12 +10:00
Fix Phase Voltage not MPPT voltage
This commit is contained in:
@@ -135,9 +135,9 @@ exports:
|
||||
- name: v5 # Temperature
|
||||
register: internal_temperature # Inverter internal temperature
|
||||
- name: v6 # Voltage
|
||||
register: mppt_1_voltage # Read voltage from first MPPT
|
||||
register: phase_a_voltage # Read voltage from first Phase
|
||||
- name: c1 # Cumulative Flag,
|
||||
value: 1 # If using v2/v4 set to 1
|
||||
value: 2 # If using v2/v4 set to 1
|
||||
# - name: "n" # Net Flag
|
||||
# value: 1
|
||||
# - name: "v7" # Extended Value v7 - Donation Only
|
||||
|
||||
@@ -216,7 +216,7 @@ registers:
|
||||
datatype: "U32"
|
||||
models: ["SG6KTL-MT", "SG8KTL-M", "SG10KTL-M", "SG10KTL-MT", "SG12KTL-M", "SG15KTL-M", "SG17KTL-M", "SG20KTL-M", "SG3.0RT", "SG4.0RT", "SG5.0RT", "SG6.0RT", "SG7.0RT", "SG8.0RT", "SG10RT", "SG12RT", "SG15RT", "SG17RT", "SG20RT", "SG33K3J", "SG36KTL-M", "SG40KTL-M", "SG50KTL", "SG50KTL-M", "SG60KTL", "SG60KTL-M", "SG60KU-M", "SG80KTL", "SG80KTL-M", "SG111HV", "SG125HV", "SG125HV-20", "SG33CX", "SG40CX", "SG50CX", "SG110CX", "SG250HX", "SG30CX", "SG36CX-US", "SG60CX-US", "SG250HX-US", "SG250HX-IN", "SG25CX-SA", "SG100CX", "SG75CX", "SG225HX"]
|
||||
- name: "mppt_1_voltage"
|
||||
level: 1
|
||||
level: 2
|
||||
address: 5011
|
||||
datatype: "U16"
|
||||
multiple: 0.1
|
||||
@@ -255,7 +255,7 @@ registers:
|
||||
address: 5017
|
||||
datatype: "S32" # Documentation says Unsigned, but seems to be returning Signed 32bit
|
||||
- name: "phase_a_voltage"
|
||||
level: 2
|
||||
level: 1
|
||||
address: 5019
|
||||
datatype: "U16"
|
||||
multiple: 0.1
|
||||
|
||||
Reference in New Issue
Block a user